JOURNAL ARTICLE

Factors influencing compliance with early resuscitation bundle in the management of severe sepsis and septic shock

Mun Ju Kang, Tae Gun Shin, Ik Joon Jo, Kyeongman Jeon, Gee Young Suh, Min Seob Sim, So Yeon Lim, Keun Jeong Song, Yeon Kwon Jeong
Shock 2012, 38 (5): 474-9
23042195
The Surviving Sepsis Campaign guidelines recommend implementing a 6-h resuscitation bundle, which has been associated with reduced mortality of patients presenting with severe sepsis or septic shock. However, this resuscitation bundle has not yet become a widely implemented treatment protocol. It is still unclear what factors are associated with the rate of compliance with the resuscitation bundle. In this study, we evaluated the potential factors associated with implementation and compliance of a 6-h resuscitation bundle in patients presenting with severe sepsis or septic shock in the emergency department. We conducted a retrospective observational study involving adult patients presenting with severe sepsis or septic shock in the emergency department of a tertiary care hospital during the period between August 2008 and July 2010. The resuscitation bundle consisted of seven interventions according to the Surviving Sepsis Campaign guidelines. The primary outcome measure was the rate of high compliance with the 6-h resuscitation bundle, defined as implementation of more than five of seven interventions. Multivariable logistic regression analysis was used to adjust for the confounding factors. A total of 317 patients were enrolled into the study. One hundred seventy-two patients (54.3%) were assigned to the high compliance group, and 145 patients (45.7%) to the low compliance group. Significant factors associated with high compliance of the 6-h resuscitation bundle were hyperthermia (adjusted odds ratio [OR], 1.37; 95% confidence interval [95% CI], 1.10-1.70), care from experienced nurses who had 3 or more years of clinical experience (adjusted OR, 1.69; 95% CI, 1.10-2.58), and care from senior residents or board-certified emergency physicians (adjusted OR, 3.68; 95% CI, 1.68-6.89). Factors related with lower compliance were cryptic shock (adjusted OR, 0.26; 95% CI, 0.13-0.52) and higher serum lactate levels (adjusted OR, 0.90; 95% CI, 0.82-0.98). Furthermore, we found several potential factors that influence compliance with the sepsis resuscitation bundle. To improve the compliance with the resuscitation bundle, interventions focusing on those factors will be needed.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
23042195
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"