JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Rapid resetting of the baroreceptors in renal hypertensive rats.

Hypertension 1990 Februrary
The characteristics and extent of rapid or acute resetting of the aortic baroreceptors were studied in long-term renal hypertensive rats during 30 minutes of sustained hypertension produced by phenylephrine infusion. The aortic baroreceptors of hypertensive rats exhibited complete resetting to hypertension because during the control period the systolic threshold pressure for activation of the baroreceptors was similar (137 +/- 5 vs. 142 +/- 4 mm Hg) to the control diastolic pressure. Five minutes after onset of hypertension, a resetting of 32% (percent change of mean pressure threshold divided by total change of mean pressure) was demonstrable. The extent of resetting was 39%, 38%, and 41% after 10, 20, and 30 minutes of hypertension, respectively. When the percent change of systolic threshold pressure divided by total change of control diastolic pressure was used to calculate the extent of resetting, similar results were obtained. The extent of displacement of the entire baroreceptor pressure-response curves was similar to that of pressure thresholds. Reversibility of the resetting process was not complete within 30 minutes of pressure normalization after the administration of phenylephrine was interrupted. These data indicate that the characteristics and extent of rapid resetting of the baroreceptors of renal hypertensive rats, which were reset to operate at hypertensive levels, are similar to those previously described in normotensive rats.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app