We have located links that may give you full text access.
CONSENSUS DEVELOPMENT CONFERENCE
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Reliability of a consensus-based ultrasound score for tenosynovitis in rheumatoid arthritis.
Annals of the Rheumatic Diseases 2013 August
OBJECTIVE: To produce consensus-based scoring systems for ultrasound (US) tenosynovitis and to assess the intraobserver and interobserver reliability of these scoring systems in rheumatoid arthritis (RA).
METHODS: We undertook a Delphi process on US-defined tenosynovitis and US scoring system of tenosynovitis in RA among 35 rheumatologists, experts in musculoskeletal US (MSUS), from 16 countries. Then, we assessed the intraobserver and interobserver reliability of US in scoring tenosynovitis on B-mode and with a power Doppler (PD) technique. Ten patients with RA with symptoms in the hands or feet were recruited. Ten rheumatologists expert in MSUS blindly, independently and consecutively scored for tenosynovitis in B-mode and PD mode three wrist extensor compartments, two finger flexor tendons and two ankle tendons of each patient in two rounds in a blinded fashion. Intraobserver reliability was assessed by Cohen's κ. Interobserver reliability was assessed by Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal.
RESULTS: Four-grade semiquantitative scoring systems were agreed upon for scoring tenosynovitis in B-mode and for scoring pathological peritendinous Doppler signal within the synovial sheath. The intraobserver reliability for tenosynovitis scoring on B-mode and PD mode was good (κ value 0.72 for B-mode; κ value 0.78 for PD mode). Interobserver reliability assessment showed good κ values for PD tenosynovitis scoring (first round, 0.64; second round, 0.65) and moderate κ values for B-mode tenosynovitis scoring (first round, 0.47; second round, 0.45).
CONCLUSIONS: US appears to be a reproducible tool for evaluating and monitoring tenosynovitis in RA.
METHODS: We undertook a Delphi process on US-defined tenosynovitis and US scoring system of tenosynovitis in RA among 35 rheumatologists, experts in musculoskeletal US (MSUS), from 16 countries. Then, we assessed the intraobserver and interobserver reliability of US in scoring tenosynovitis on B-mode and with a power Doppler (PD) technique. Ten patients with RA with symptoms in the hands or feet were recruited. Ten rheumatologists expert in MSUS blindly, independently and consecutively scored for tenosynovitis in B-mode and PD mode three wrist extensor compartments, two finger flexor tendons and two ankle tendons of each patient in two rounds in a blinded fashion. Intraobserver reliability was assessed by Cohen's κ. Interobserver reliability was assessed by Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal.
RESULTS: Four-grade semiquantitative scoring systems were agreed upon for scoring tenosynovitis in B-mode and for scoring pathological peritendinous Doppler signal within the synovial sheath. The intraobserver reliability for tenosynovitis scoring on B-mode and PD mode was good (κ value 0.72 for B-mode; κ value 0.78 for PD mode). Interobserver reliability assessment showed good κ values for PD tenosynovitis scoring (first round, 0.64; second round, 0.65) and moderate κ values for B-mode tenosynovitis scoring (first round, 0.47; second round, 0.45).
CONCLUSIONS: US appears to be a reproducible tool for evaluating and monitoring tenosynovitis in RA.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app