RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

The accuracy of human senses in the detection of neonatal heart rate during standardized simulated resuscitation: implications for delivery of care, training and technology design.

Resuscitation 2013 March
AIM: Auscultation and palpation are recommended methods of determining heart rate (HR) during neonatal resuscitation. We hypothesized that: (a) detection of HR by auscultation or palpation will vary by more than ± 15BPM from actual HR; and (b) the inability to accurately determine HR will be associated with errors in management of the neonate during simulated resuscitation.

SUBJECTS AND METHODS: Using a prospective, randomized, controlled study design, 64 subjects participated in three simulated neonatal resuscitation scenarios. Subjects were randomized to technique used to determine HR (auscultation or palpation) and scenario order. Subjects verbalized their numeric assessment of HR at the onset of the scenario and after any intervention. Accuracy of HR determination and errors in resuscitation were recorded. Errors were classified as errors of omission (lack of appropriate interventions) or errors of commission (inappropriate interventions). Cochran's Q and chi square test were used to compare HR detection by method and across scenarios.

RESULTS: Errors in HR determination occurred in 26-48% of initial assessments and 26-52% of subsequent assessments overall. There were neither statistically significant differences in accuracy between the two techniques of HR assessment (auscultation vs palpation) nor across the three scenarios. Of the 90 errors in resuscitation, 43 (48%) occurred in association with errors in HR determination.

CONCLUSIONS: Determination of heart rate via auscultation and palpation by experienced healthcare professionals in a neonatal patient simulator with standardized cues is not reliable. Inaccuracy in HR determination is associated with errors of omission and commission. More reliable methods for HR assessment during neonatal resuscitation are required.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app