OBJECTIVE: The aim of this study is to find out if an ultrasound technique has advantages over the conventional landmark technique.
METHODS: This is a prospective randomized comparative study on 120 patients requiring central venous cannulation of the right internal jugular vein. The study comprised of two groups: ultrasound and landmark groups, each consisting of 60 patients. The outcome measures were compared between the groups.
RESULTS: Cannulation of the internal jugular vein was successful in 58 patients in the ultrasound group and in 53 in the landmark group. The number of attempts was 1.5 (1 - 3) and 2 (1 - 3) in the ultrasound and landmark group respectively (p = 0.001). The time taken for the successful cannulation was 4.9 +/- 1.7 minutes in the ultrasound approach and 8.0 +/- 2.8 minutes in the landmark approach (p = 0.00). The internal jugular vein diameter in the supine position was 11.2 +/- 1.5 mm which increased to 15.04 +/- 1.5 mm with a 15 degrees head-down position in the USG group (p = 0.001). The first attempt success rate was 39/60 (63%) in the ultrasound group and 19/60 (32%) with the landmark technique. The seven (12%) failure cases in the landmark group were rescued by the ultrasound technique. Inadvertent carotid artery puncture occurred in 2/60 (3%) and 6/60 (10%) of patients in the ultrasound and land mark group respectively.
CONCLUSIONS: Ultrasound improves success rate, minimizes cannulation time and complications during internal jugular vein cannulation. It can be employed as a rescue technique in cases of a failed landmark technique.
METHODS: This is a prospective randomized comparative study on 120 patients requiring central venous cannulation of the right internal jugular vein. The study comprised of two groups: ultrasound and landmark groups, each consisting of 60 patients. The outcome measures were compared between the groups.
RESULTS: Cannulation of the internal jugular vein was successful in 58 patients in the ultrasound group and in 53 in the landmark group. The number of attempts was 1.5 (1 - 3) and 2 (1 - 3) in the ultrasound and landmark group respectively (p = 0.001). The time taken for the successful cannulation was 4.9 +/- 1.7 minutes in the ultrasound approach and 8.0 +/- 2.8 minutes in the landmark approach (p = 0.00). The internal jugular vein diameter in the supine position was 11.2 +/- 1.5 mm which increased to 15.04 +/- 1.5 mm with a 15 degrees head-down position in the USG group (p = 0.001). The first attempt success rate was 39/60 (63%) in the ultrasound group and 19/60 (32%) with the landmark technique. The seven (12%) failure cases in the landmark group were rescued by the ultrasound technique. Inadvertent carotid artery puncture occurred in 2/60 (3%) and 6/60 (10%) of patients in the ultrasound and land mark group respectively.
CONCLUSIONS: Ultrasound improves success rate, minimizes cannulation time and complications during internal jugular vein cannulation. It can be employed as a rescue technique in cases of a failed landmark technique.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app