Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

Medical Physics 2012 August
PURPOSE: Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in clinical routine. For follow-up CT exams a prior scan is often available. It typically contains the same anatomical structures, just somewhat deformed and not aligned. This work describes a two-step technique that utilizes this prior scan to achieve high-quality low-dose CT imaging, overcoming difficulties arising from noise artifacts and misalignment. We specifically focus on reducing the dose by lowering the number of projections. This gives rise to severe streak artifacts which possibly lower the readability of CT images to a larger extent than the fine-grained noise that results from lowering the mA or kV settings.

METHODS: A common approach is to apply image filtering to reduce the noise artifacts. These techniques typically utilize pixel neighborhoods in the degraded image to estimate the true value of a pixel at the center of this neighborhood. However, this can lead to poor results when the image is severely contaminated under very low low-dose situations. We propose a method that utilizes the nondegraded, clean prior to determine higher quality pixel statistics to form the pixel estimates, supported by the matching scheme of the non-local means filter. To make this matching reliable, a good registration of prior and low-dose image is required. For this, we employ a state-of-the-art registration method, called SIFT-flow, which can tolerate the high amount of streak noise. But even for properly registered images, using an artifact free prior for the matching yields inferior results. We hence describe a scheme that first constructs a tandem-prior with streak artifacts resembling those in the low-dose image, and then employs this image for the matching, but uses the corresponding high-quality prior to determine the pixel estimates.

RESULTS: Two experimental studies are carried out, using a head phantom and a human lung with projections gathered via simulation. We assess the quality of the processed reconstruction with various metrics: mathematical and perceptual. We find that the quality that can be obtained with the artifact-matched prior-based scheme significantly exceeds that of all competing schemes. Even though the general prior-based approach is able to eliminate the streak artifacts, only the artifact-matched scheme can restore small detail and feature sharpness.

CONCLUSIONS: The reduced-projection low-dose image reconstruction algorithm we present outperforms traditional image restoration algorithms when a prior scan is available. Our method is quite efficient and as such it is well suited for fast-paced clinical applications such as image-assisted interventions, orthopedic alignment scans, and follow-ups.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app