Quantification of echodensities in tuberculous pericardial effusion using fractal geometry: a proof of concept study.

BACKGROUND: The purpose of this study was to quantify the heterogeneous distribution of echodensities in the pericardial fluid of patients with tuberculous pericarditis using echocardiography and fractal analysis, and to determine whether there were differences in the fractal dimensions of effusive-constrictive and effusive non-constrictive disease.

METHODS: We used fractal geometry to quantify the echocardiographic densities in patients who were enrolled in the Investigation of the Management of Pericarditis in Africa (IMPI Africa) Registry. Sub-costal and four chamber images were included in the analysis if a minimum of two clearly identified fibrin strands were present and the quality of the images were of a standard which allowed for accurate measurement of the fractal dimension. The fractal dimension was calculated as follows: D(f) = limlog N(s)/[log (l/s)], where D(f) is the box counting fractal dimension of the fibrin strand, s is the side length of the box and N(s) is the smallest number of boxes of side length s to cover the outline of the object being measured. We compared the fractal dimension of echocardiographic findings in patients with effusive constrictive pericarditis to effusive non-constrictive pericardial effusion using the non-parametric Mann-Whitney test.

RESULTS: Of the 14 echocardiographs from 14 participants that were selected for the study, 42.8% (6/14) of images were subcostal views while 57.1% (8/14) were 4-chamber views. Eight of the patients had tuberculous effusive constrictive pericarditis while 6 had tuberculous effusive non-constrictive pericarditis. The mean fractal dimension D(f) was 1.325 with a standard deviation (SD) of 0.146. The measured fibrin strand dimension exceeded the topological dimension in all the images over the entire range of grid scales with a correlation coefficient (r2) greater than 0.8 in the majority. The fractal dimension of echodensities was 1.359 ± 0.199 in effusive constrictive pericarditis compared to 1.330 ± 0.166 in effusive non-constrictive pericarditis (p = 0.595).

CONCLUSIONS: The echocardiographic densities in tuberculous pericardial effusion have a fractal geometrical dimension which is similar in pure effusive and effusive constrictive disease.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app