Intra-biliary contrast-enhanced ultrasound for evaluating biliary obstruction during percutaneous transhepatic biliary drainage: a preliminary study.
European Journal of Radiology 2012 December
OBJECTIVES: The aimed of this study was to investigate the value of intra-biliary contrast-enhanced ultrasound (IB-CEUS) for evaluating biliary obstruction during percutaneous transhepatic biliary drainage (PTBD).
MATERIALS AND METHODS: 80 patients with obstructive jaundice who underwent IB-CEUS during PTBD were enrolled. The diluted ultrasound contrast agent was injected via the drainage catheter to perform IB-CEUS. Both conventional ultrasound and IB-CEUS were used to detect the tips of the drainage catheters and to compare the detection rates of the tips. The obstructive level and degree of biliary tract were evaluated by IB-CEUS. Fluoroscopic cholangiography (FC) and computer tomography cholangiography (CTC) were taken as standard reference for comparison.
RESULTS: Conventional ultrasound displayed only 43 tips (43/80, 53.8%) of the drainage catheters within the bile ducts while IB-CEUS identified all 80 tips (80/80, 100%) of the drainage catheters including 4 of them out of the bile duct (P<0.001). IB-CEUS made correct diagnosis in 44 patients with intrahepatic and 36 patients with extrahepatic biliary obstructions. IB-CEUS accurately demonstrated complete obstruction in 56 patients and incomplete obstruction in 21 patients. There were 3 patients with incomplete obstruction misdiagnosed to be complete obstruction by IB-CEUS. The diagnostic accuracy of biliary obstruction degree was 96.3% (77/80).
CONCLUSION: IB-CEUS could improve the visualization of the drainage catheters and evaluate the biliary obstructive level and degree during PTBD. IB-CEUS may be the potential substitute to FC in the PTBD procedure.
MATERIALS AND METHODS: 80 patients with obstructive jaundice who underwent IB-CEUS during PTBD were enrolled. The diluted ultrasound contrast agent was injected via the drainage catheter to perform IB-CEUS. Both conventional ultrasound and IB-CEUS were used to detect the tips of the drainage catheters and to compare the detection rates of the tips. The obstructive level and degree of biliary tract were evaluated by IB-CEUS. Fluoroscopic cholangiography (FC) and computer tomography cholangiography (CTC) were taken as standard reference for comparison.
RESULTS: Conventional ultrasound displayed only 43 tips (43/80, 53.8%) of the drainage catheters within the bile ducts while IB-CEUS identified all 80 tips (80/80, 100%) of the drainage catheters including 4 of them out of the bile duct (P<0.001). IB-CEUS made correct diagnosis in 44 patients with intrahepatic and 36 patients with extrahepatic biliary obstructions. IB-CEUS accurately demonstrated complete obstruction in 56 patients and incomplete obstruction in 21 patients. There were 3 patients with incomplete obstruction misdiagnosed to be complete obstruction by IB-CEUS. The diagnostic accuracy of biliary obstruction degree was 96.3% (77/80).
CONCLUSION: IB-CEUS could improve the visualization of the drainage catheters and evaluate the biliary obstructive level and degree during PTBD. IB-CEUS may be the potential substitute to FC in the PTBD procedure.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app