COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial.

BACKGROUND: In patients with sinus rhythm and normal atrioventricular conduction, pacing only the left ventricle with appropriate atrioventricular delays can result in superior left ventricular and right ventricular function compared with standard biventricular (BiV) pacing.

OBJECTIVE: To evaluate a novel adaptive cardiac resynchronization therapy ((aCRT) algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular or BiV pacing with dynamic optimization of atrioventricular and interventricular delays.

METHODS: Patients (n = 522) indicated for a CRT-defibrillator were randomized to aCRT vs echo-optimized BiV pacing (Echo) in a 2:1 ratio and followed at 1-, 3-, and 6-month postrandomization.

RESULTS: The study met all 3 noninferiority primary objectives: (1) the percentage of aCRT patients who improved in their clinical composite score at 6 months was at least as high in the aCRT arm as in the Echo arm (73.6% vs 72.5%, with a noninferiority margin of 12%; P = .0007); (2) aCRT and echo-optimized settings resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between aortic velocity time integrals at aCRT and Echo settings at randomization (concordance correlation coefficient = 0.93; 95% confidence interval 0.91-0.94) and at 6-month postrandomization (concordance correlation coefficient = 0.90; 95% confidence interval 0.87-0.92); and (3) aCRT did not result in inappropriate device settings. There were no significant differences between the arms with respect to heart failure events or ventricular arrhythmia episodes. Secondary end points showed similar benefit, and right-ventricular pacing was reduced by 44% in the aCRT arm.

CONCLUSIONS: The aCRT algorithm is safe and at least as effective as BiV pacing with comprehensive echocardiographic optimization.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app