First-in-man experience with a new 7F vascular closure device (EXOSEAL™): the 7F ECLIPSE study.
Journal of Interventional Cardiology 2012 October
OBJECTIVE: This feasibility study examined safety and effectiveness of the new EXOSEAL™ Vascular Closure Device (VCD) designed to promote hemostasis and early ambulation after percutaneous procedures.
BACKGROUND: Most VCDs currently approved by the United States FDA have been associated with significantly shorter time-to-hemostasis (TTH) and time-to-ambulation (TTA) compared to standard manual or mechanical compression, but their ease of use, patient comfort during deployment, and safety profiles are variable.
METHODS: Patients underwent diagnostic or interventional procedures using 7F introducer sheaths. Primary safety endpoint was the 30-day combined rate of access-related complications and primary effectiveness endpoints were TTH and TTA.
RESULTS: Sixty patients were enrolled prospectively (mean age 63.3 ± 11.3 year, 17% diabetics). Device and procedural success was achieved in 92% and 93%, respectively. Mean TTH and TTA was 3.2 ± 3.0 minutes and 3.0 ± 6.2 hours, respectively. No deaths or serious access-related adverse events occurred. A ≥6 cm access-site hematoma was the only adverse event, observed in 3 patients.
CONCLUSIONS: Use of the 7F EXOSEAL™ VCD was associated with short TTH and TTA, as well as low rates of procedural and 30-day access-related complications.
BACKGROUND: Most VCDs currently approved by the United States FDA have been associated with significantly shorter time-to-hemostasis (TTH) and time-to-ambulation (TTA) compared to standard manual or mechanical compression, but their ease of use, patient comfort during deployment, and safety profiles are variable.
METHODS: Patients underwent diagnostic or interventional procedures using 7F introducer sheaths. Primary safety endpoint was the 30-day combined rate of access-related complications and primary effectiveness endpoints were TTH and TTA.
RESULTS: Sixty patients were enrolled prospectively (mean age 63.3 ± 11.3 year, 17% diabetics). Device and procedural success was achieved in 92% and 93%, respectively. Mean TTH and TTA was 3.2 ± 3.0 minutes and 3.0 ± 6.2 hours, respectively. No deaths or serious access-related adverse events occurred. A ≥6 cm access-site hematoma was the only adverse event, observed in 3 patients.
CONCLUSIONS: Use of the 7F EXOSEAL™ VCD was associated with short TTH and TTA, as well as low rates of procedural and 30-day access-related complications.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app