Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Healing responses after bifurcation stenting with the dedicated TRYTON Side-Branch Stent™ in combination with XIENCE-V™ stents: a clinical, angiography, fractional flow reserve, and optical coherence tomography study: the PYTON (Prospective evaluation of the TRYTON Side-Branch Stent™ with an additional XIENCE-v™ everolimus-eluting stent in coronary bifurcation lesions) study.

OBJECTIVES: We evaluated healing responses with optical coherence tomography (OCT), and clinical and angiographic outcome after bifurcation stenting with the TRYTON Side-Branch Stent™.

BACKGROUND: Dedicated bifurcation stents have been proposed as a potential alternative for treatment of true coronary bifurcation lesions.

METHODS: We treated 20 consecutive patients with coronary bifurcation lesions and significant involvement of the side-branch (SB) with the TRYTON Stent and an additional XIENCE-V™ everolimus-eluting stent. At 9 months, we assessed the ratio of uncovered to total stent struts (RUTSS) with OCT, angiographic late luminal loss (LLL), and in-stent and in-segment restenosis. Clinical endpoints at 1 year included major adverse cardiac events (MACE) and their components [target lesion revascularization (TLR), myocardial infarction (MI), and cardiac death].

RESULTS: LLL (N = 16) was 0.34 (0.17-0.46), 0.29 (0.24-0.48) and 0.57 (0.29-0.73) mm in the proximal main vessel (MV), distal MV and SB, respectively. In-bifurcation binary in-stent restenosis occurred in four patients (25%), in-segment restenosis in five (31.25%). The RUTSS (N = 13) was 4.0 ± 5.8, 0.7 ± 1.3, 0, and 2.5 ± 3.6% in the proximal MV, distal MV, SB, and polygon of confluence, respectively. At 1 year, MACE occurred in 5 (25%) [4 TLR (20%), 3 MI (15%)].

CONCLUSION: The homogeneous stent strut coverage and the low LLL in the MV reflect proper healing characteristics of the TRYTON Stent in combination with the XIENCE-V™ stent. However, proximal MV edge and ostial SB restenoses together with overall clinical outcomes do not fulfill expectations of a dedicated bifurcation stent. © 2012 Wiley Periodicals, Inc.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app