We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
Motion generated in the unstable cervical spine during the application and removal of cervical immobilization collars.
Journal of Trauma and Acute Care Surgery 2012 June
BACKGROUND: Many studies have compared the restriction of motion that immobilization collars provide to the injured victim. No previous investigation has assessed the amount of motion that is generated during the fitting and removal process. The purpose of this study was to compare the three-dimensional motion generated when one-piece and two-piece cervical collars are applied and removed from cadavers intact and with unstable cervical spine injuries.
METHODS: Five fresh, lightly embalmed cadavers were tested three times each with either a one-piece or two-piece cervical collar in the supine position. Testing was performed in the intact state, following creation of a global ligamentous instability at C5-C6. The amount of angular motion resulting from the collar application and removal was measured using a Fastrak, three-dimensional, electromagnetic motion analysis device (Polhemus Inc., Colchester, VT). The measurements recorded in this investigation included maximum values for flexion/extension, axial rotation, medial/lateral flexion, anterior/posterior displacement, axial distraction, and medial/lateral displacement at the level of instability.
RESULTS: There was statistically more motion observed with application or removal of either collar following the creation of a global instability. During application, there was a statistically significant difference in flexion/extension between the one-piece (1.8 degrees) and two-piece (2.6 degrees) collars, p = 0.009. There was also a statistically significant difference in anterior/posterior translation between the one-piece (3.6 mm) and two-piece (3.4 mm) collars, p = 0.015. The maximum angulation and displacement during the application of either collar was 3.4 degrees and 4.4 mm. Statistical analysis revealed no significant differences between the one-piece and two-piece collars during the removal process. The maximum angulation and displacement during removal of either collar type was 1.6 degrees and 2.9 mm.
CONCLUSIONS: There were statistically significant differences in motion between the one-piece and two-piece collars during the application process, but it was only 1.2 degrees in flexion/extension and 0.2 mm in anterior/posterior translation. Overall, the greatest amount of angulation and displacement observed during collar application was 3.4 degrees and 4.4 mm. Although the exact amount of motion that could be deleterious to a cervical spine-injured patient is unknown, collars can be placed and removed with manual in-line stabilization without large displacements. Only trained practitioners should do so and with great care given that some motion in all planes does occur during the process.
METHODS: Five fresh, lightly embalmed cadavers were tested three times each with either a one-piece or two-piece cervical collar in the supine position. Testing was performed in the intact state, following creation of a global ligamentous instability at C5-C6. The amount of angular motion resulting from the collar application and removal was measured using a Fastrak, three-dimensional, electromagnetic motion analysis device (Polhemus Inc., Colchester, VT). The measurements recorded in this investigation included maximum values for flexion/extension, axial rotation, medial/lateral flexion, anterior/posterior displacement, axial distraction, and medial/lateral displacement at the level of instability.
RESULTS: There was statistically more motion observed with application or removal of either collar following the creation of a global instability. During application, there was a statistically significant difference in flexion/extension between the one-piece (1.8 degrees) and two-piece (2.6 degrees) collars, p = 0.009. There was also a statistically significant difference in anterior/posterior translation between the one-piece (3.6 mm) and two-piece (3.4 mm) collars, p = 0.015. The maximum angulation and displacement during the application of either collar was 3.4 degrees and 4.4 mm. Statistical analysis revealed no significant differences between the one-piece and two-piece collars during the removal process. The maximum angulation and displacement during removal of either collar type was 1.6 degrees and 2.9 mm.
CONCLUSIONS: There were statistically significant differences in motion between the one-piece and two-piece collars during the application process, but it was only 1.2 degrees in flexion/extension and 0.2 mm in anterior/posterior translation. Overall, the greatest amount of angulation and displacement observed during collar application was 3.4 degrees and 4.4 mm. Although the exact amount of motion that could be deleterious to a cervical spine-injured patient is unknown, collars can be placed and removed with manual in-line stabilization without large displacements. Only trained practitioners should do so and with great care given that some motion in all planes does occur during the process.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app