Reliability of 3-dimensional transvaginal sonographic measurement of lower uterine segment thickness.

OBJECTIVES: The purpose of this study was to report the intraobserver and interobserver reliability of transvaginal 3-dimensional (3D) sonographic measurement of lower uterine segment thickness.

METHODS: A prospective study of 60 pregnant women with previous low transverse cesarean deliveries was performed between 35 and 39 weeks' gestation. Two observers, blinded to the clinical data, independently measured the full lower uterine segment thickness by 2-dimensional (2D) transvaginal sonography. Three-dimensional volume data sets of the lower uterine segment were captured and analyzed more than 2 months later by both observers independently. Intraobserver, interobserver, and intermethod reliability was evaluated by median absolute differences, nonparametric limits of agreement, intraclass correlation coefficients (ICCs), and κ coefficients.

RESULTS: The median full lower uterine segment thickness was 3.6 mm (range, 0.9-8.0 mm). Intraobserver reliability (median difference, 0.3 mm [interquartile range (IQR), 0.1-0.6 mm]; ICC, 0.88 [95% confidence interval (CI), 0.81-0.93]; κ, 0.87 [95% CI, 0.69-1.00]) and interobserver reliability (median difference, 0.3 mm [IQR, 0.1-0.5 mm]; ICC, 0.88 [95% CI, 0.81-0.93]; κ, 0.86 [95% CI, 0.66-1.00]) were excellent. Reliability between 3D and 2D sonography was moderate (median difference, 0.6 mm [IQR, 0.2-0.9 mm]; ICC, 0.78 [95% CI, 0.66-0.86]; κ, 0.56 [95% CI, 0.28-0.85]). However, intermethod reproducibility was improved when the full lower uterine segment thickness was less than 3.0 mm (median difference, 0.4 mm [IQR, 0.2-0.9 mm]).

CONCLUSIONS: Full lower uterine segment thickness measured with 3D transvaginal sonographic data sets has excellent intraobserver and interobserver reliability. It also has good reproducibility with 2D sonography when the full lower uterine segment thickness is less than 3.0 mm.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app