Add like
Add dislike
Add to saved papers

Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images.

PURPOSE: To study the performance of dual-energy indirect computed tomography (CT) venography from single-source dual-energy CT in the assessment of lower extremity deep venous thrombosis (DVT).

MATERIALS AND METHODS: In a retrospective study, 110 patients suspected to have pulmonary embolism (PE) underwent dual-energy CT venography on a single-source dual-energy CT scanner as a part of CT pulmonary angiography protocol at 3 minutes after injection of contrast material. Two radiologists evaluated 50-kiloelectron volt (keV) and 70-keV monochromatic images reconstructed from a dual-energy CT scan for image quality, image noise, venous contrast, and confidence level in interpretation for DVT using a scale of 1-5. In addition, a combined 50-keV and 70-keV data set was assessed for confidence level in image interpretation. Attenuation, contrast-to-noise ratio (CNR), and objective noise were measured in bilateral common femoral and popliteal veins. Data were analyzed using Student t test and Wilcoxon rank sum test. Radiation dose was measured for dual-energy CT venography protocol.

RESULTS: A diagnosis of DVT was made in 8 of 110 patients (7.27%). The subjective image quality was comparable between 50-keV and 70-keV images (4.3 vs 4.5; P > .05). The subjective venous contrast opacification (4.7 vs 3.5; P = .0036) and confidence (4.8 vs 3.9; P = .0028) in image interpretation were superior at 50 keV. Confidence level for interpretation on combined 50-keV and 70-keV series (score 4.7) was similar to that for 50-keV series (score 4.8). Compared with 70-keV data, 50-keV data yielded 90% increase in intravascular CT attenuation (207.4 Hounsfield units [HU] ± 39.0 vs 106.8 HU ± 7.6; P <.0001) and higher CNR (10.7 ± 4.07 vs 7.2 ± 4.1; P = .0001) of the deep veins. However, objective noise at 50 keV was higher (14.8 HU vs 6.5 HU; P = .0031). Because of inadequate contrast opacification, 6% of CT venography studies were deemed suboptimal for rendering a diagnostic interpretation on 70-keV images, but these images were considered acceptable at 50 keV. The mean effective radiation dose for the dual-energy CT venography examination was 4.2 mSv.

CONCLUSIONS: Optimal image quality with substantially higher venous attenuation is provided by 50-keV monochromatic images from dual-energy CT venography acquisition compared with 70-keV images. The 50-keV monochromatic images increase the confidence in the image interpretation of DVT and decrease the number of indeterminate studies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app