A comparison of several methods of macular hole measurement using optical coherence tomography, and their value in predicting anatomical and visual outcomes.
British Journal of Ophthalmology 2012 July
BACKGROUND/AIMS: To compare several methods of macular hole measurement using optical coherence tomography (OCT), and to assess their predictive capability against anatomical and visual outcomes in a single cohort of patients.
METHODS: A retrospective study of 50 eyes undergoing standardised macular hole surgery. All patients underwent preoperative OCT scanning with measurement of macular hole inner opening diameter, minimum linear diameter, base diameter and macular hole height. Values were calculated for the macular hole index and the tractional hole index.
RESULTS: Logistic regression analyses indicated that the preoperative base diameter, macular hole inner opening and minimum linear diameter were associated with both anatomical and visual success. Derived parameters as alternatives to these basic ophthalmic parameters add little to the modelling of either anatomical or visual success.
CONCLUSION: Base diameter, macular hole inner opening and minimum linear diameter can each be used to predict anatomical and/or functional success in macular hole surgery. Preoperative base diameter is the most useful variable in this regard, as it holds the strongest association with anatomical and visual outcome and is easily measured on a OCT scan.
METHODS: A retrospective study of 50 eyes undergoing standardised macular hole surgery. All patients underwent preoperative OCT scanning with measurement of macular hole inner opening diameter, minimum linear diameter, base diameter and macular hole height. Values were calculated for the macular hole index and the tractional hole index.
RESULTS: Logistic regression analyses indicated that the preoperative base diameter, macular hole inner opening and minimum linear diameter were associated with both anatomical and visual success. Derived parameters as alternatives to these basic ophthalmic parameters add little to the modelling of either anatomical or visual success.
CONCLUSION: Base diameter, macular hole inner opening and minimum linear diameter can each be used to predict anatomical and/or functional success in macular hole surgery. Preoperative base diameter is the most useful variable in this regard, as it holds the strongest association with anatomical and visual outcome and is easily measured on a OCT scan.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app