MENU ▼
Read by QxMD icon Read
search
OPEN IN READ APP
COMPARATIVE STUDY
JOURNAL ARTICLE

Measurement of optic disc size and rim area with spectral-domain OCT and scanning laser ophthalmoscopy

Sasan Moghimi, Hamid Hosseini, Jay Riddle, Gina Yoo Lee, Elena Bitrian, JoAnn Giaconi, Joseph Caprioli, Kouros Nouri-Mahdavi
Investigative Ophthalmology & Visual Science 2012, 53 (8): 4519-30
22577077

PURPOSE: To compare optic disc and neuroretinal rim area measurements from spectral-domain optical coherence tomography (SD-OCT) to those from confocal scanning laser ophthalmoscopy.

METHODS: Seventy-one eyes from 43 normal subjects or suspected/definite glaucoma patients were prospectively enrolled. All subjects had biometry with the IOLMaster and disc/retinal nerve fiber layer imaging with Cirrus SD-OCT (Optic Disc Cube 200×200) and Heidelberg Retina Tomograph (HRT). Uncorrected disc and rim areas and measurements corrected for eye magnification with Bennett's formula (AL-corrected measurements), along with 30° sectoral rim areas, vertical cup-to-disc ratio (VCDR), and cup volume, were compared between the two devices.

RESULTS: The median (range) axial length (AL) was 24.2 mm (22.4-27.7 mm). Mean keratometry-corrected HRT disc area measurements were larger than AL-corrected HRT and SD-OCT measurements (P < 0.001 for both) and the difference was a function of keratometry measurements (K-readings). The AL-corrected HRT disc area and uncorrected/corrected Cirrus disc areas were not significantly different (P > 0.481). HRT rim area was larger than Cirrus measurements (P < 0.001) and the difference decreased with decreasing rim area. HRT VCDR and cup volume were significantly smaller than Cirrus measurements (P < 0.001). The correlations for sectoral rim areas between the two devices were moderate at best (intraclass correlation coefficients = 0.12-0.65).

CONCLUSIONS: HRT overestimated optic disc area as compared to SD-OCT. A portion of the difference in HRT and SD-OCT disc measurements is due to HRT's magnification correction algorithm. Rim area measurements from HRT were larger than from SD-OCT, likely a result of different definitions for the reference plane and differences in disc area measurements. Disc parameters from the two devices are not interchangeable.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
22577077
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"