We have located links that may give you full text access.
Clinical Trial
Journal Article
Efficacy and durability of endovascular thoracoabdominal aortic aneurysm repair using the caudally directed cuff technique.
Journal of Vascular Surgery 2012 July
OBJECTIVE: This study determined early and intermediate results of multibranched endovascular thoracoabdominal (TAAA) and pararenal aortic aneurysm (PRAA) repair using a uniform operative technique.
METHODS: Eighty-one patients (mean age, 73 ± 8 years, 19 [23.5%] women) underwent endovascular TAAA repair in a prospective trial using self-expanding covered stents connecting axially oriented, caudally directed cuffs to target aortic branches. Mean aneurysm diameter was 67 ± 10 mm. Thirty-nine TAAA (48.1%) were Crawford type II, III, or V; 42 (51.9%) were type IV or pararenal. Thirty-three procedures (40.7%) were staged. The insertion approach was femoral for aortic components and brachial for branch components. Follow-up assessments were performed at 1, 6, and 12 months, and yearly thereafter.
RESULTS: All devices (n = 81) and branches (n = 306) were successfully inserted and deployed, with no conversions to open repair. Overall mortality was 6.2% (n = 5), including three perioperative (3.7%) and two late treatment-related deaths (2.5%). Permanent paraplegia occurred in three patients (3.7%), and transient paraplegia/paraparesis occurred in 16 (19.8%). Four patients (4.9%) required dialysis postoperatively, three permanently and one transiently. Women accounted for 67% of the paraplegia, 75% of the perioperative dialysis, and 60% of the perioperative or treatment-related deaths. During a mean follow-up of 21.2 months, no aneurysms ruptured, but four (4.9%) enlarged: two were successfully treated, one was unsuccessfully treated, and one was not treated. No late onset spinal cord ischemia symptoms developed. Of the five patients starting dialysis during follow-up, two resulted from renal branch occlusion. Sixteen branches occluded (nine renal, two celiac) or developed stenoses (four renal, one superior mesenteric artery), requiring stenting. Primary patency was 94.8%, and primary-assisted patency was 95.1%. Thirty-two patients (39.5%) underwent 42 reinterventions. Of 25 early reinterventions (≤ 45 days), 10 were to treat access or insertion complications, and 5 were for endoleak. Of 17 late reinterventions, eight were for endoleak and five were for branch stenosis/occlusion. New endoleaks developed in two patients during follow-up. Overall, 73 of 81 patients (90.1%) were treated without procedure-related death, dialysis, paralysis, aneurysm rupture, or conversion to open repair.
CONCLUSIONS: Total endovascular TAAA/PRAA repair using caudally directed cuffs is safe, effective, and durable in the intermediate term. The most common form of late failure, renal artery occlusion, rarely had a clinically significant consequence (dialysis). The trend toward worse outcome in women needs further study.
METHODS: Eighty-one patients (mean age, 73 ± 8 years, 19 [23.5%] women) underwent endovascular TAAA repair in a prospective trial using self-expanding covered stents connecting axially oriented, caudally directed cuffs to target aortic branches. Mean aneurysm diameter was 67 ± 10 mm. Thirty-nine TAAA (48.1%) were Crawford type II, III, or V; 42 (51.9%) were type IV or pararenal. Thirty-three procedures (40.7%) were staged. The insertion approach was femoral for aortic components and brachial for branch components. Follow-up assessments were performed at 1, 6, and 12 months, and yearly thereafter.
RESULTS: All devices (n = 81) and branches (n = 306) were successfully inserted and deployed, with no conversions to open repair. Overall mortality was 6.2% (n = 5), including three perioperative (3.7%) and two late treatment-related deaths (2.5%). Permanent paraplegia occurred in three patients (3.7%), and transient paraplegia/paraparesis occurred in 16 (19.8%). Four patients (4.9%) required dialysis postoperatively, three permanently and one transiently. Women accounted for 67% of the paraplegia, 75% of the perioperative dialysis, and 60% of the perioperative or treatment-related deaths. During a mean follow-up of 21.2 months, no aneurysms ruptured, but four (4.9%) enlarged: two were successfully treated, one was unsuccessfully treated, and one was not treated. No late onset spinal cord ischemia symptoms developed. Of the five patients starting dialysis during follow-up, two resulted from renal branch occlusion. Sixteen branches occluded (nine renal, two celiac) or developed stenoses (four renal, one superior mesenteric artery), requiring stenting. Primary patency was 94.8%, and primary-assisted patency was 95.1%. Thirty-two patients (39.5%) underwent 42 reinterventions. Of 25 early reinterventions (≤ 45 days), 10 were to treat access or insertion complications, and 5 were for endoleak. Of 17 late reinterventions, eight were for endoleak and five were for branch stenosis/occlusion. New endoleaks developed in two patients during follow-up. Overall, 73 of 81 patients (90.1%) were treated without procedure-related death, dialysis, paralysis, aneurysm rupture, or conversion to open repair.
CONCLUSIONS: Total endovascular TAAA/PRAA repair using caudally directed cuffs is safe, effective, and durable in the intermediate term. The most common form of late failure, renal artery occlusion, rarely had a clinically significant consequence (dialysis). The trend toward worse outcome in women needs further study.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app