Add like
Add dislike
Add to saved papers

A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer.

AIM: To prospectively compare volumetric intensity-modulated arc therapy (VMAT) and conventional intensity-modulated radiation therapy (IMRT) in coverage of planning target volumes and avoidance of multiple organs at risk (OARs) in patients undergoing definitive chemoradiotherapy for advanced (stage III or IV) squamous cell cancer of the head and neck.

METHODS: Computed tomography scans of 20 patients with advanced tumors of the larynx, naso-, oro- and hypopharynx were prospectively planned using IMRT (7 field) and VMAT using two arcs. Calculated doses to planning target volume (PTV) and OAR were compared between IMRT and VMAT plans. Dose-volume histograms (DVH) were utilized to obtain calculated doses to PTV and OAR, including parotids, cochlea, spinal cord, brainstem, anterior tongue, pituitary and brachial plexus. DVH's for all structures were compared between IMRT and VMAT plans. In addition the plans were compared for dose conformity and homogeneity. The final treatment plan was chosen by the treating radiation oncologist.

RESULTS: VMAT was chosen as the ultimate plan in 18 of 20 patients (90%) because the plans were thought to be otherwise clinically equivalent. The IMRT plan was chosen in 2 of 20 patients because the VMAT plan produced concentric irradiation of the cord which was not overcome even with an avoidance structure. For all patients, VMAT plans had a lower number of average monitor units on average (MU = 542.85) than IMRT plans (MU = 1612.58) (P < 0.001). Using the conformity index (CI), defined as the 95% isodose volume divided by the PTV, the IMRT plan was more conformal with a lower conformity index (CI = 1.61) than the VMAT plan (CI = 2.00) (P = 0.003). Dose homogeneity, as measured by average standard deviation of dose distribution over the PTV, was not different with VMAT (1.45 Gy) or IMRT (1.73 Gy) (P = 0.069). There were no differences in sparing organs at risk.

CONCLUSION: In this prospective study, VMAT plans were chosen over IMRT 90% of the time. Compared to IMRT, VMAT plans used only one third of the MUs, had shorter treatment times, and similar sparing of OAR. Overall, VMAT provided similar dose homogeneity but less conformity in PTV irradiation compared to IMRT. This difference in conformity was not clinically significant.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app