JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Add like
Add dislike
Add to saved papers

Efficient construction of PET/fluorescence probe based on sarcophagine cage: an opportunity to integrate diagnosis with treatment.

PURPOSE: Due to the shortage of established platforms/methods for multimodality probe construction, in this study, we developed a heterofunctional chelator, BaAn(Boc)Sar, from sarcophagine cage as a general platform for dual-modality probe construction.

PROCEDURES: A dual-modality probe for positron-emission tomography (PET) and fluorescence imaging was synthesized using the developed BaAn(Boc)Sar chelator. The c(RGDyK)(2) peptide (denoted as RGD(2)) and fluorescence dye Cy5.5 were conjugated with BaAn(Boc)Sar to form BaAnSar-RGD(2)-Cy5.5. Then, BaAnSar-RGD(2)-Cy5.5 was labeled with (64)Cu in ammonium acetate buffer. PET and fluorescent imaging were carried out to evaluate (64)Cu-BaAnSar-RGD(2)-Cy5.5 in nude mice bearing U87MG glioblastoma xenograft.

RESULTS: The BaAnSar-RGD(2)-Cy5.5 was labeled with (64)Cu very efficiently in 0.1 M NH(4)OAc buffer within 10 min at 37 °C in the yield of 86.7 ± 4.4 % (n = 3). The specific activity of (64)Cu-BaBaSar-RGD(2) was controlled at 50-200 mCi/μmol for the consideration of both PET and optical imaging. MicroPET quantification analysis shows that the U87MG tumor uptake is 6.41 ± 0.28, 6.51 ± 1.45, and 5.92 ± 1.57 %ID/g at 1, 4, and 20 h postinjection, respectively. Good correlation was obtained between the tumor to muscle ratios measured by the radioactivity and fluorescence intensity. As a proof of concept, an animal surgery study demonstrated that this dual-modality probe would greatly benefit the patients because the PET moiety could be used for tumor detection, and the fluorescent moiety would allow image-guided surgery.

CONCLUSIONS: Our findings demonstrated the effectiveness and feasibility of preparing dual-modality imaging probes based on the sarcophagine scaffold. The resulting PET and fluorescent imaging probe also holds a great potential for clinical translation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app