BACKGROUND: In an attempt to improve patient outcome and quality of life after laparoscopic ventral hernia repair, resorbable fixation devices have been developed to allow adequate mesh fixation while minimizing accompanying side-effects as tack erosion and adhesion formation.

MATERIALS AND METHODS: In experimental set-up, 24 pigs were treated by laparoscopic mesh placement. Two different meshes (PP/ORC and PP/ePTFE) and four fixation devices were evaluated: a 6.4 mm poly(D,L: )-lactide pushpin (tack I), a 6.8 mm poly(D,L: )-lactide with blunt tip (tack II), a 4.1 mm poly(glycolide-co-L-lactide) (tack III) and one titanium tack (control tack). A first group of animals (n = 12) was euthanized after 2 weeks survival and a second group (n = 12) after 6 months. At euthanasia, a relaparoscopy was performed to assess adhesion formation followed by laparotomy with excision of the entire abdominal wall. Tensile strength of the individual fixation systems was tested with the use of a tensiometer by measuring the force to pull the tack out of the mesh. Additionally, the foreign body reaction to the fixation systems was evaluated histologically as was their potential degradation.

RESULTS: At 2 weeks the tensile strength was significantly higher for the control tack (31.98 N/cm²) compared to the resorbable devices. Except for tack II, the tensile strength was higher when the devices were fixed in a PP/ePTFE mesh compared to the PP/ORC mesh. After 6 months only tack III was completely resorbed, while tack I (9.292 N/cm²) had the lowest tensile strength. At this time-point similar tensile strength was observed for both tack II (29.56 N/cm²) and the control tack (27.77 N/cm²). Adhesions seem to be more depending on the type of mesh, in favor of PP/ePTFE.

CONCLUSION: At long term, the 4.1 mm poly(glycolide-co-L-lactide) tack was the only tack completely resorbed while the 6.8 mm poly(D,L: )-lactide tack with blunt tip reached equal strengths to the permanent tack.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app