We have located links that may give you full text access.
CASE REPORTS
JOURNAL ARTICLE
Lysis of the orbicularis retaining ligament and orbicularis oculi insertion: a powerful modality for lower eyelid and cheek rejuvenation.
Plastic and Reconstructive Surgery 2012 April
BACKGROUND: The techniques of lower blepharoplasty are evolving to reflect the concept that the lower eyelid contour does not stop at the inferior orbital rim, and that the lid-cheek junction must often be modified to restore the midface to a youthful configuration. Multiple procedures have been proposed to smooth the lid-cheek junction and tear trough. The author proposes a technique of carbon dioxide laser lysis of the orbicularis retaining ligament and of the orbicularis oculi insertion onto the maxilla to release the tethering of the lower lid and cheek and allow recontouring of the lid-cheek junction in an extended transcutaneous lower blepharoplasty.
METHODS: Retrospective review of 80 extended lower blepharoplasty procedures with carbon dioxide laser lysis of the orbicularis retaining ligament and of the orbicularis oculi insertion performed in the past 3 years was undertaken. Follow-up ranged from 4 to 26 months, with an average of 7.2 months. The efficacy, risks, and complications of this procedure were assessed.
RESULTS: The complication rate for this procedure is not significantly higher than that for standard transcutaneous blepharoplasty, and the procedure allows significant improvement of the lid-cheek junction and rejuvenation of the upper midface.
CONCLUSIONS: Lysis of the orbicularis retaining ligament and lower orbicularis oculi insertion is a safe and effective adjunct to lower blepharoplasty. It is a powerful modality that allows significant rejuvenation of the lid-cheek complex and upper cheek.
CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
METHODS: Retrospective review of 80 extended lower blepharoplasty procedures with carbon dioxide laser lysis of the orbicularis retaining ligament and of the orbicularis oculi insertion performed in the past 3 years was undertaken. Follow-up ranged from 4 to 26 months, with an average of 7.2 months. The efficacy, risks, and complications of this procedure were assessed.
RESULTS: The complication rate for this procedure is not significantly higher than that for standard transcutaneous blepharoplasty, and the procedure allows significant improvement of the lid-cheek junction and rejuvenation of the upper midface.
CONCLUSIONS: Lysis of the orbicularis retaining ligament and lower orbicularis oculi insertion is a safe and effective adjunct to lower blepharoplasty. It is a powerful modality that allows significant rejuvenation of the lid-cheek complex and upper cheek.
CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app