COMPARATIVE STUDY
JOURNAL ARTICLE

Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation

Y-F Tsai, B-C Su, C-C Lin, F-C Liu, W-C Lee, H-P Yu
Transplantation Proceedings 2012, 44 (2): 433-7
22410036

BACKGROUND: The upgraded third-generation software (version 3.02) for the FloTrac/Vigileo system has been developed to particularly improve the accuracy of cardiac output (CO) measurements in hyperdynamic conditions. The aim of our study was to compare the CO values obtained using the FloTrac/Vigileo system during orthotopic liver transplantation (OLT) with those obtained in the same circumstances using a Swan-Ganz catheter (bolus thermodilution method).

METHODS: Twenty consecutive recipients scheduled for OLT were studied. Simultaneous CO values measured by both devices were obtained at 10 predefined time points throughout the surgery. A percentage error of not more than 30% was established as the criterion for device interchangeability.

RESULTS: A total of 200 paired measurements were obtained. The CO values derived from the FloTrac/Viligeo ranged from 2.8 to 10.9 L/min, with a mean of 5.91±1.81 L/min. The values from bolus thermodilution ranged from 2.2 to 13.2 L/min, with a mean of 6.12±2.07 L/min. The bias was 0.22, and the limits of agreement were -3.13 to 3.56 L/min. The percentage error between the FloTrac/Viligeo and bolus thermodilution measurements was 54.93%. The percentage errors of paired measurements in three surgical phases by subgroup analysis were 43.50% (dissecting phase), 62.9% (anhepatic phase), and 56.05% (reperfusion phase), respectively.

CONCLUSION: CO measurements obtained using the less invasive arterial waveform FloTrac/Vigileo system upgraded with the third-generation software had poor intraoperative agreement with pulmonary artery thermodilution CO measurements in patients undergoing OLT.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
22410036
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"