Intraoperative MRI electrical noise and monitor ECG filters affect arrhythmia detection and identification.

Most electrical equipment in the modern operating room (OR) radiates electrical noise (EN) that can interfere with patient monitors. We have described the EN that an intraoperative magnetic resonance imaging (iMRI) system emits and have shown that this high-energy EN diminishes the quality of the ECG waveform during iMRI scans in our neurosurgical OR. We have also shown that the ECG signal filters in our iMRI-compatible patient monitor reduce this interference but, in the process, disturb the true morphology of the displayed waveform. This simulation study evaluates how iMRI-generated EN affects the ability of the anesthetist to detect and identify ECG arrhythmias and whether the patient monitor's ECG signal filters can improve arrhythmia recognition. Using an ECG simulator, we generated Lead II and V5 ECG signal segments that contained either no arrhythmia or one of four common cardiac arrhythmias. We filtered the ECG segments with four filters available on our iMRI-compatible monitor (Veris MR, MEDRAD Inc., Indianola, PA USA). We then digitized the segments and mixed simulated iMRI EN into the resultant tracings. With institutional approval and written informed consent, board-certified anesthesiologists reviewed the tracings, determined if an arrhythmia was present and identified the arrhythmia. We conducted the study anonymously. We reported the data as percent correct arrhythmia detection and correct arrhythmia identification. Thirty-one anesthesiologists completed the study. Overall, the participants correctly detected 79.5% (95% CI: 77.2, 81.7%) of the arrhythmias and correctly identified 62.5% (95% CI: 59.8, 65.3%) of the arrhythmias, regardless of EN presence. Although the proportions among monitor noise filters studied were not significant, the manufacturer-designated MR5 Veris MR filter optimized arrhythmia detection and arrhythmia identification for our participants, regardless if EN was present in the ECG tracings. In the neurosurgical OR, the anesthetist must be able to effectively monitor a patient in the presence of iMRI-generated EN. Depending on the OR design, the patient may be out of the anesthetist's direct view during a scan procedure. The anesthetist must rely on monitored physiologic parameters to assess patient status during this time. He/she should be familiar with his/her monitor's filtering capabilities and routinely adjust the ECG filters to achieve the best compromise between minimized EN effects and maximized displayed ECG signal quality.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app