Inaccuracy of estimating peak work rate from six-minute walk distance in patients with COPD.
COPD 2012 June
INTRODUCTION: The cardiopulmonary exercise test (CPET) and the 6-minute walk test (6MWT) are used to prescribe the appropriate training load for cycling and walking exercise in patients with chronic obstructive pulmonary disease (COPD). The primary aims were: (i) to compare estimated peak work rate (Wpeak(estimated)) derived from six existing Wpeak regression equations with actual peak work rate (Wpeak(actual)); and (ii) to derive a new Wpeak regression equation using six-minute walk distance (6MWD) and conventional outcome measures in COPD patients.
METHODS: In 2906 patients with COPD, existing Wpeak regression equations were used to estimate Wpeak using 6MWD and a new equation was derived after a stepwise multiple regression analysis.
RESULTS: The 6 existing Wpeak regression equations were inaccurate to predict Wpeak(actual) in 82% of the COPD patients. The new Wpeak regression equation differed less between Wpeak(estimated) and Wpeak(actual) compared to existing models. Still, in 74% of COPD patients Wpeak(estimated) and Wpeak(actual) differed more than (±) 5 watts.
CONCLUSION: In conclusion, estimating peak work load from 6MWD in COPD is inaccurate. We recommend assessment of Wpeak using CPET during pre-rehabilitation assessment in addition to 6MWT.
METHODS: In 2906 patients with COPD, existing Wpeak regression equations were used to estimate Wpeak using 6MWD and a new equation was derived after a stepwise multiple regression analysis.
RESULTS: The 6 existing Wpeak regression equations were inaccurate to predict Wpeak(actual) in 82% of the COPD patients. The new Wpeak regression equation differed less between Wpeak(estimated) and Wpeak(actual) compared to existing models. Still, in 74% of COPD patients Wpeak(estimated) and Wpeak(actual) differed more than (±) 5 watts.
CONCLUSION: In conclusion, estimating peak work load from 6MWD in COPD is inaccurate. We recommend assessment of Wpeak using CPET during pre-rehabilitation assessment in addition to 6MWT.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app