We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
Intravascular ultrasound lumen area parameters for assessment of physiological ischemia by fractional flow reserve in intermediate coronary artery stenosis.
BACKGROUND: A fractional flow reserve (FFR) of <0.8 is currently used to guide revascularization in lesions with intermediate coronary stenosis. Whether there is an intravascular ultrasound (IVUS) measurement or a cutoff value that can reliably determine which of these intermediate lesions requires intervention is unclear.
AIMS: We assessed IVUS measurement accuracy in defining functional ischemia by FFR.
METHODS: The analysis included 205 intermediate lesions (185 patients) located in vessel diameters >2.5 mm. Positive FFR was considered present at <0.8. IVUS measurements were correlated to the FFR findings in intermediate lesions with 40%-70% stenosis. Fifty-four (26.3%) lesions had FFR<0.8.
RESULTS: There was moderate correlation between FFR and IVUS measurements, including minimum lumen area (MLA) (r=0.36, P<.001), minimum lumen diameter (MLD) (r=0.25, P=<.001), lesion length (r=-0.43, P<.001), and area stenosis (r=-0.33, P=.01). A receiver operating characteristic curve (ROC) identified MLA<3.09 mm(2) (sensitivity 69.2%, specificity 79.5%) as the best threshold value for FFR<0.8. The correlation between FFR and IVUS was better for large vessels compared to small vessels. ROC analysis identified the best threshold value for FFR<0.8 of MLA<2.4 mm(2) [area under curve (AUC)=0.74] in lesions with reference vessel diameters of 2.5-3 mm, MLA<2.7 mm(2) (AUC=0.77) in lesions with reference vessel diameters of 3-3.5 mm, and MLA<3.6 mm(2) (AUC=0.70) in lesions with reference vessel diameters >3.5 mm.
CONCLUSION: Anatomic measurements of intermediate coronary lesions obtained by IVUS show a moderate correlation to FFR values. The correlation was better for larger-diameter vessels. Vessel size should always be taken into account when determining the MLA associated with functional ischemia.
AIMS: We assessed IVUS measurement accuracy in defining functional ischemia by FFR.
METHODS: The analysis included 205 intermediate lesions (185 patients) located in vessel diameters >2.5 mm. Positive FFR was considered present at <0.8. IVUS measurements were correlated to the FFR findings in intermediate lesions with 40%-70% stenosis. Fifty-four (26.3%) lesions had FFR<0.8.
RESULTS: There was moderate correlation between FFR and IVUS measurements, including minimum lumen area (MLA) (r=0.36, P<.001), minimum lumen diameter (MLD) (r=0.25, P=<.001), lesion length (r=-0.43, P<.001), and area stenosis (r=-0.33, P=.01). A receiver operating characteristic curve (ROC) identified MLA<3.09 mm(2) (sensitivity 69.2%, specificity 79.5%) as the best threshold value for FFR<0.8. The correlation between FFR and IVUS was better for large vessels compared to small vessels. ROC analysis identified the best threshold value for FFR<0.8 of MLA<2.4 mm(2) [area under curve (AUC)=0.74] in lesions with reference vessel diameters of 2.5-3 mm, MLA<2.7 mm(2) (AUC=0.77) in lesions with reference vessel diameters of 3-3.5 mm, and MLA<3.6 mm(2) (AUC=0.70) in lesions with reference vessel diameters >3.5 mm.
CONCLUSION: Anatomic measurements of intermediate coronary lesions obtained by IVUS show a moderate correlation to FFR values. The correlation was better for larger-diameter vessels. Vessel size should always be taken into account when determining the MLA associated with functional ischemia.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app