18F-Fluorodeoxyglucose positron emission tomography pulmonary imaging in idiopathic pulmonary fibrosis is reproducible: implications for future clinical trials

Thida Win, Tryphon Lambrou, Brian F Hutton, Irfan Kayani, Nicholas J Screaton, Joanna C Porter, Toby M Maher, Raymondo Endozo, Robert I Shortman, Pauline Lukey, Ashley M Groves
European Journal of Nuclear Medicine and Molecular Imaging 2012, 39 (3): 521-8
22258710

PURPOSE: Noninvasive markers of disease activity in patients with idiopathic pulmonary fibrosis (IPF) are lacking. We performed this study to investigate the reproducibility of pulmonary (18)F-FDG PET/CT in patients with IPF.

METHODS: The study group comprised 13 patients (11 men, 2 women; mean age 71.1 ± 9.9 years) with IPF recruited for two thoracic (18)F-FDG PET/CT studies performed within 2 weeks of each other. All patients were diagnosed with IPF in consensus at multidisciplinary meetings as a result of typical clinical, high-resolution CT and pulmonary function test features. Three methods for evaluating pulmonary (18)F-FDG uptake were used. The maximal (18)F-FDG pulmonary uptake (SUVmax) in the lungs was determined using manual region-of-interest placement. An (18)F-FDG uptake intensity histogram was automatically constructed from segmented lungs to evaluate the distribution of SUVs. Finally, mean SUV was determined for volumes-of-interest in pulmonary regions with interstitial lung changes identified on CT scans. Processing included correction for tissue fraction effects. Bland-Altman analysis was performed and interclass correlation coefficients (ICC) were determined to assess the reproducibility between the first and second PET scans, as well as the level of intraobserver and interobserver agreement.

RESULTS: The mean time between the two scans was 6.3 ± 4.3 days. The interscan ICCs for pulmonary SUVmax analysis and mean SUV corrected for tissue fraction effects were 0.90 and 0.91, respectively. Intensity histograms were different in only 1 of the 13 paired studies. Intraobserver agreement was also excellent (0.80 and 0.85, respectively). Some bias was observed between observers, suggesting that serial studies would benefit from analysis by the same observer.

CONCLUSION: This study demonstrated that there is excellent short-term reproducibility in pulmonary (18)F-FDG uptake in patients with IPF.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
22258710
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.