Volumetric modulated arc therapy for nasopharyngeal carcinoma: a dosimetric comparison with TomoTherapy and step-and-shoot IMRT.

PURPOSE: Volumetric modulated arc therapy (VMAT), a novel technique, employs a linear accelerator to conduct dynamic modulation rotation radiotherapy. The goal of this study was to compare VMAT with helical tomotherapy (HT) and step-and-shoot intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) patients with regard to the sparing effect on organs at risk (OARs), dosimetric quality, and efficiency of delivery.

MATERIALS AND METHODS: Twenty patients with NPC treated by HT were re-planned by VMAT (two arcs) and IMRT (7-9 fields) for dosimetric comparison. The target area received three dose levels (70, 60, and 54 Gy) in 33 fractions using simultaneous integrated boosts technique. The Philips Pinnacle Planning System 9.0 was adopted to design VMAT, using SmartArc as the planning algorithm. For a fair comparison, the planning target volume (PTV) coverage of the 3 plans was normalized to the same level. Dosimetric comparisons between VMAT, HT, and IMRT plans were analyzed to evaluate (1) coverage, homogeneity, and conformity of PTV, (2) sparing of OARs, (3) delivery time, and (4) monitor units (MUs).

RESULTS: The VMAT, HT, and IMRT plans had similar PTV coverage with an average of 96%. There was no significant difference between VMAT and HT in homogeneity, while the homogeneity indices of VMAT (1.06) and HT (1.06) were better than IMRT plans (1.07, p<0.05). HT plans provided a better conformity index (1.17) than VMAT (1.28, p=0.01) and IMRT (1.36, p=0.02). When compared with IMRT, VMAT and HT had a better sparing effect on brain stem and spinal cord (p<0.05). The effect of parotid sparing was similar between VMAT (mean=26.3 Gy) and HT (mean=27.5 Gy), but better than IMRT (mean=31.3 Gy, p<0.01). The delivery time per fraction for VMAT (5.7 min) were much lower than for HT (9.5 min, p<0.01) and IMRT (9.2 min, p<0.01).

CONCLUSIONS: Our results indicate that VMAT provides better sparing of normal tissue, homogeneity, and conformity than IMRT, and shorter delivery time than HT.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app