COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
RANDOMIZED CONTROLLED TRIAL

Head-to-head comparison of the neointimal response between metallic and bioresorbable everolimus-eluting scaffolds using optical coherence tomography

Josep Gomez-Lara, Salvatore Brugaletta, Vasim Farooq, Yoshinobu Onuma, Roberto Diletti, Stephan Windecker, Leif Thuesen, Dougal McClean, Jacques Koolen, Robert Whitbourn, Dariusz Dudek, Pieter C Smits, Bernard Chevalier, Evelyn Regar, Susan Veldhof, Richard Rapoza, John A Ormiston, Hector M Garcia-Garcia, Patrick W Serruys
JACC. Cardiovascular Interventions 2011, 4 (12): 1271-80
22192368

OBJECTIVES: This study sought to compare the neointimal response of metallic everolimus drug-eluting stents (DES) and polymeric everolimus bioresorbable vascular scaffolds (BVS) by optical coherence tomography at 1 year.

BACKGROUND: DES decrease the risk of restenosis by reducing the neointimal response. However, DES may impair strut coverage, and this has been associated with late stent/scaffold thrombosis. BVS may overcome the risk of stent/scaffold thrombosis when completely resorbed. It is unknown if, during the bioresorption process, the neointimal response of the everolimus BVS (Absorb, Abbott Vascular, Santa Clara, California) differs from that of the metallic everolimus DES (Xience, Abbott Vascular).

METHODS: A total of 19 lesions were treated with a single everolimus DES, and 31 lesions were treated with everolimus BVS and imaged with optical coherence tomography at 1 year. Neointimal response was assessed as percentage of uncovered struts, neointimal thickness, in-stent/scaffold area obstruction, and pattern of neointima.

RESULTS: At 1 year, no significant differences in the angiographic lumen loss were seen for the everolimus DES and everolimus BVS (0.18 ± 0.20 mm vs. 0.29 ± 0.36 mm; p = 0.42). optical coherence tomography analysis of 951 cross sections and 8,385 struts demonstrated similar rates of uncovered struts (5.3% everolimus DES vs. 4.5% everolimus BVS; p = 0.11), mean neointimal thickness (120.6 ± 46.0 μm vs. 136.1 ± 71.4 μm; p = 0.82) and in-stent/scaffold area obstruction (12.5 ± 7.1% vs. 13.6 ± 9.7%; p = 0.91), respectively. There was a trend of higher heterogenic tissue pattern of neointima (21.1% vs. 6.5%; p = 0.12) and less intraluminal masses (0% vs. 12.9%; p = 0.10) with everolimus DES than with everolimus BVS.

CONCLUSIONS: The everolimus BVS (Absorb) demonstrated a similar neointimal response as the everolimus DES (Xience). However, the presence of intraluminal masses at 12 months in a small proportion of patients warranted watchful follow-up of these cases.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
22192368
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"