We have located links that may give you full text access.
JOURNAL ARTICLE
MULTICENTER STUDY
Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.
Journal of Vascular Surgery 2012 March
BACKGROUND: To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization.
METHODS: Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic endograft, thereby creating a conduit that runs outside the aortic main endograft, and has been proposed to ensure secure proximal fixation extending the sealing zones.
RESULTS: Forty-six consecutive target vessels (43 renal arteries and 3 superior mesenteric arteries) were revascularized by the Advanta (Atrium, Hudson, NH) BECS (1.2 chimneys/patient); in contrast, 81 consecutive target vessels (64 renal arteries, 11 superior mesenteric arteries, and 6 celiac trunks) were revascularized by the Viabahn (Gore, Flagstaff, Ariz) SECS (2.3 chimneys/patient). The success rate for target vessel preservation was 97.8% for the BECS group and 100% for the SECS group in the entire follow up. There was one symptomatic left renal artery occlusion of the BECS group treated by open thrombectomy of the left renal artery and placement of 8-mm Dacron (BBraun, Aesculap AG, Tuttlingen, Germany) iliorenal bypass. Additionally, one patient underwent repeat balloon angioplasty with a 5-mm balloon due to high-grade in-stent stenosis of a 6 × 59 Advanta stent graft 12 months postoperatively. Overall, one perioperative (and not present in the computed tomography angiography at discharge) type Ia endoleak was detected in the BECS group. In contrast, five perioperative type Ia endoleaks were present in the SECS group; however, only one of them was persistent in the radiological imaging and was treated by proximal extension of a 5-mm cuff, 1 year postoperatively, due to continuous aneurismal sac increase. No patient of any subgroup developed postoperative persistent renal insufficiency with need of hemodialysis. Thirty-day and during the follow-up procedure-related mortality was 0% for both BECS and SECS groups.
CONCLUSIONS: In summary, midterm results of use of covered chimney stents for pararenal aortic pathologies show safety and feasibility with excellent patency and low incidence of endoleaks.
METHODS: Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic endograft, thereby creating a conduit that runs outside the aortic main endograft, and has been proposed to ensure secure proximal fixation extending the sealing zones.
RESULTS: Forty-six consecutive target vessels (43 renal arteries and 3 superior mesenteric arteries) were revascularized by the Advanta (Atrium, Hudson, NH) BECS (1.2 chimneys/patient); in contrast, 81 consecutive target vessels (64 renal arteries, 11 superior mesenteric arteries, and 6 celiac trunks) were revascularized by the Viabahn (Gore, Flagstaff, Ariz) SECS (2.3 chimneys/patient). The success rate for target vessel preservation was 97.8% for the BECS group and 100% for the SECS group in the entire follow up. There was one symptomatic left renal artery occlusion of the BECS group treated by open thrombectomy of the left renal artery and placement of 8-mm Dacron (BBraun, Aesculap AG, Tuttlingen, Germany) iliorenal bypass. Additionally, one patient underwent repeat balloon angioplasty with a 5-mm balloon due to high-grade in-stent stenosis of a 6 × 59 Advanta stent graft 12 months postoperatively. Overall, one perioperative (and not present in the computed tomography angiography at discharge) type Ia endoleak was detected in the BECS group. In contrast, five perioperative type Ia endoleaks were present in the SECS group; however, only one of them was persistent in the radiological imaging and was treated by proximal extension of a 5-mm cuff, 1 year postoperatively, due to continuous aneurismal sac increase. No patient of any subgroup developed postoperative persistent renal insufficiency with need of hemodialysis. Thirty-day and during the follow-up procedure-related mortality was 0% for both BECS and SECS groups.
CONCLUSIONS: In summary, midterm results of use of covered chimney stents for pararenal aortic pathologies show safety and feasibility with excellent patency and low incidence of endoleaks.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app