We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Stroke-related changes in neuromuscular fatigue of the hip flexors and functional implications.
OBJECTIVE: The aim of this study was to compare stroke-related changes in hip flexor neuromuscular fatigue of the paretic leg during a sustained isometric submaximal contraction with those of the nonparetic leg and controls and to correlate fatigue with clinical measures of function.
DESIGN: Hip torques were measured during a fatiguing hip flexion contraction at 20% of the hip flexion maximal voluntary contraction in the paretic and nonparetic legs of 13 people with chronic stroke and 10 age-matched controls. In addition, the participants with stroke performed a fatiguing contraction of the paretic leg at the absolute torque equivalent to 20% maximal voluntary contraction of the nonparetic leg and were tested for self-selected walking speed (10-m Walk Test) and balance (Berg).
RESULTS: When matching the nonparetic target torque, the paretic hip flexors had a shorter time to task failure compared with the nonparetic leg and controls (P < 0.05). The time to failure of the paretic leg was inversely correlated with the reduction of hip flexion maximal voluntary contraction torque. Self-selected walking speed was correlated with declines in torque and steadiness. Berg-Balance scores were inversely correlated with the force fluctuation amplitude.
CONCLUSIONS: Fatigue and precision of contraction are correlated with walking function and balance after stroke.
DESIGN: Hip torques were measured during a fatiguing hip flexion contraction at 20% of the hip flexion maximal voluntary contraction in the paretic and nonparetic legs of 13 people with chronic stroke and 10 age-matched controls. In addition, the participants with stroke performed a fatiguing contraction of the paretic leg at the absolute torque equivalent to 20% maximal voluntary contraction of the nonparetic leg and were tested for self-selected walking speed (10-m Walk Test) and balance (Berg).
RESULTS: When matching the nonparetic target torque, the paretic hip flexors had a shorter time to task failure compared with the nonparetic leg and controls (P < 0.05). The time to failure of the paretic leg was inversely correlated with the reduction of hip flexion maximal voluntary contraction torque. Self-selected walking speed was correlated with declines in torque and steadiness. Berg-Balance scores were inversely correlated with the force fluctuation amplitude.
CONCLUSIONS: Fatigue and precision of contraction are correlated with walking function and balance after stroke.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.