The sensitivity and specificity of ultrasound estimation of central venous pressure using the internal jugular vein.
Journal of Critical Care 2012 June
PURPOSE: The fluid volume status of a patient is difficult to assess clinically. The aim of this study was to compare the ultrasound estimation of the height of the right internal jugular vein (CVP(IJV)) with direct estimation of central venous pressure (CVP) (CVP(CVC)).
MATERIALS AND METHODS: A portable ultrasound machine defined the "top" of the right internal jugular vein in 44 patients from a single tertiary hospital. The vertical height from this point to the sternal angle was used to estimate CVP(IJV). A central venous catheter was then inserted and direct measurement of CVP was made with a pressure transducer. A normal CVP was defined as 3 to 6 mm Hg.
RESULTS: For overloaded patients, CVP(IJV) correlated well with CVP(CVC), P = .004, sensitivity of 64.3%, specificity of 81.3%, and positive predictive value of 85.7%. The area under the curve for the receiver operating characteristic curve was 0.73 (95% confidence interval, 0.59-0.86). For undervolumed patients, the correlation remained statistically significant, P < .001, sensitivity of 88.9%, specificity of 77.1%, and negative predictive value of 96.4%. The area under the curve was 0.83 (95% confidence interval, 0.70-0.96).
CONCLUSION: Ultrasound estimation of CVP using a portable ultrasound machine and the internal jugular vein is simple, noninvasive, and accurate.
MATERIALS AND METHODS: A portable ultrasound machine defined the "top" of the right internal jugular vein in 44 patients from a single tertiary hospital. The vertical height from this point to the sternal angle was used to estimate CVP(IJV). A central venous catheter was then inserted and direct measurement of CVP was made with a pressure transducer. A normal CVP was defined as 3 to 6 mm Hg.
RESULTS: For overloaded patients, CVP(IJV) correlated well with CVP(CVC), P = .004, sensitivity of 64.3%, specificity of 81.3%, and positive predictive value of 85.7%. The area under the curve for the receiver operating characteristic curve was 0.73 (95% confidence interval, 0.59-0.86). For undervolumed patients, the correlation remained statistically significant, P < .001, sensitivity of 88.9%, specificity of 77.1%, and negative predictive value of 96.4%. The area under the curve was 0.83 (95% confidence interval, 0.70-0.96).
CONCLUSION: Ultrasound estimation of CVP using a portable ultrasound machine and the internal jugular vein is simple, noninvasive, and accurate.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app