JOURNAL ARTICLE
MULTICENTER STUDY
Add like
Add dislike
Add to saved papers

Transapical aortic valve implantation in high-risk patients with severe aortic valve stenosis.

BACKGROUND: Transapical aortic valve implantation (TA-TAVI) represents an alternative in patients with symptomatic severe aortic valve stenosis (SSAVS) who cannot be operated on or have a high surgical risk. The aim of this prospective multicenter observational study was to assess early and 2-year clinical and hemodynamic outcomes after TA-TAVI.

METHODS: From May 2008 to September 2010, 179 patients with inoperable conditions or high-risk patients underwent TA-TAVI at 4 institutions. Indications for TA-TAVI were SSAVS and logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) greater than 20% or porcelain aorta in patients with severe aortoiliac disease. Patients underwent clinical and echocardiographic follow-up visits at hospital discharge, 3 and 6 months after TA-TAVI, and every 6 months thereafter. The impact of the learning curve for the centers and of intraoperative complications on patient outcomes was also evaluated.

RESULTS: Mean age was 81 ± 6 years. Mean logistic EuroSCORE was 22% ± 12%. Transapical delivery was successful in all patients. Seventeen severe intraoperative complications occurred in 13 (7.3%) patients. Thirty-day mortality was 3.9% (7 patients). Mean follow-up was 9.2 ± 6.5 months. Late mortality occurred in 9 patients. Two-year survival was 88% ± 3%. An intraoperative severe complication was identified as the only significant independent predictor of 1-year mortality. A significant benefit was found when comparing 2-year survival of the second versus the first 50% patients at each center (93% ± 2% versus 84% ± 3 %; p = 0.046). A significant reduction of both mean and peak gradients from the preoperative to the postoperative period, which remained stable during follow-up, was found.

CONCLUSIONS: TA-TAVI provides excellent early and 2-year results in terms of survival, valve-related adverse events, and hemodynamic performance. Survival after TA-TAVI is affected by the center learning curve and by the occurrence of an intraoperative complication.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app