CLINICAL TRIAL
COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Success rates and endotracheal tube insertion times of experienced emergency physicians using five video laryngoscopes: a randomised trial in a simulated trapped car accident victim.

CONTEXT: No randomised controlled trial has yet compared different video laryngoscopes in respect of the success rates and the time taken to achieve endotracheal intubation in trapped car accident victims.

OBJECTIVE: The aim of the present study was to evaluate whether five video laryngoscopes facilitate tracheal intubation more quickly or more securely than conventional laryngoscopy.

DESIGN: Prospective, controlled, randomised crossover trial.

SETTING: An airway manikin was placed on the driver's seat of a compact car. Access was possible only through the opened driver's door.

PARTICIPANTS: Twenty-five experienced anaesthetists.

INTERVENTION: Tracheal intubation in a simulated trapped patient using video laryngoscopes in a typical out-of-hospital setting.

MAIN OUTCOME MEASURES: Times to achievement of a view of the glottis, tracheal intubation, cuff inflation, first ventilation and tracheal tube position were compared using a standard Macintosh laryngoscope or Glidescope Ranger, Storz C-MAC, Ambu-Pentax AWS, Airtraq and McGrath Series 5 video laryngoscopes in a randomised order. Wilcoxon signed-rank test and McNemar test were used for statistical analysis. A P value of less than 0.05 was considered statistically significant.

RESULTS: Twenty-five anaesthetists (35.1 ± 7.3 years; 16 male, nine female) with an intubation experience of 374 ± 96 intubations per year and an experience of 9.1 ± 7.3 years participated. Glottic view, tracheal intubation, cuff inflation and first ventilation were achieved most rapidly with the Macintosh laryngoscope, although the Airtraq and Pentax AWS video laryngoscopes were not significantly slower. Times were significantly longer when the Glidescope Ranger, McGrath Series 5 or Storz C-MAC video laryngoscopes were used (P < 0.05), failure to place the endotracheal tube correctly was significantly commoner with the McGrath Series 5 than with the Macintosh (P = 0.031).

CONCLUSION: When attempting to intubate a trapped car accident victim, video laryngoscopes provide a better view of the glottis, but some delay tracheal intubation significantly. The devices with a tube guide (Airtraq and Ambu Pentax AWS) enable tracheal intubation to be achieved significantly faster and with a lower failure rate than devices without a tube guide. No video laryngoscope outperformed direct laryngoscopy with a Macintosh laryngoscope in this simulation study.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app