Journal Article
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Cardiac resynchronization therapy reduces left atrial volume and the risk of atrial tachyarrhythmias in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).

OBJECTIVES: We hypothesized that reductions in left atrial volume (LAV) with a cardiac resynchronization therapy-defibrillator (CRT-D) would translate into a subsequent reduction in the risk of atrial tachyarrhythmias (AT).

BACKGROUND: There is limited information regarding the effect of CRT-D on the risk of AT.

METHODS: Percent reduction in LAV at 1 year following CRT-D implantation (pre-specified as low [lowest quartile: <20% reduction in LAV] and high [≥20% reduction in LAV] response to CRT-D) were related to the risk of subsequent AT (comprising atrial fibrillation, atrial flutter, atrial tachycardia, and supraventricular tachyarrhythmias) among patients enrolled in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).

RESULTS: The cumulative probability of AT 2.5 years after assessment of echocardiographic response was lowest among high LAV responders to CRT-D (3%) and significantly higher among both low LAV responders to CRT-D (9%) and implantable cardioverter-defibrillator-only patients (7%; p = 0.03 for the difference among the 3 groups). Consistently, multivariate analysis showed that high LAV responders to CRT-D experienced a significant 53% (p = 0.01) reduction in the risk of subsequent AT as compared with implantable cardioverter-defibrillator-only patients, whereas low LAV responders did not derive a significant risk reduction with CRT-D therapy (hazard ratio [HR]: 1.05 [95% confidence interval (CI): 0.54 to 2.00]; p = 0.89). Patients who developed in-trial AT experienced significant increases in the risk for both the combined endpoint of heart failure or death (HR: 2.28 [95% CI: 1.45 to 3.59]; p < 0.001) and the separate occurrence of all-cause mortality (HR: 1.89 [95% CI: 1.08 to 3.62]; p = 0.01).

CONCLUSIONS: In the MADIT-CRT study, favorable reverse remodeling of the left atrium with CRT-D therapy was associated with a significant reduction in risk of subsequent AT. (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app