Hook plate fixation for acromioclavicular joint separations restores coracoclavicular distance more accurately than PDS augmentation, however presents with a high rate of acromial osteolysis.

INTRODUCTION: Hook plate fixation of acromioclavicular (AC) joint separations carries the disadvantage of compulsory implant removal, occasional implant fatigue and secondary loss of reduction. This study compares the clinical and radiological outcome of a new polyaxial angular stable hook plate (HP) with absorbable polydioxansulfate (PDS) sling.

MATERIALS AND METHODS: Between 2002 and 2009, out of a consecutive series of 81 patients with symptomatic Rockwood type V lesions 52 patients received clinical and radiographic follow-up (HP: n = 27; PDS: n = 25). HP patients were prospectively analyzed and retrospectively compared with the PDS group. Radiological follow-up included comparative coraco- and acromioclavicular distance (CCD/ACD) measurements as percentage of the uninjured shoulder. For clinical follow-up a standardized functional shoulder assessment with Constant Score, DASH Score, Taft Score and a self-report questionnaire including the visual analog scale (VAS) was carried out.

RESULTS: Direct postoperative radiographs showed an overcorrection of CCD in the HP group (-4.4% of the uninjured side) and failure of anatomic correction in the PDS group (+11.0%). After implant removal, CCD increased in the HP group extensively to 16.7% (overall loss of reduction: 21.1%) and 23.9% in the PDS group. Redisplacement (100% increase of CCD) occurred in five cases (HP: 2, PDS: 3) and partial loss of reduction in four cases of each group. Comparing functional results no differences could be seen between both the groups (Constant-Score HP: 91.2 points, PDS: 94.6 points; Taft-Score HP: 9.4 points, PDS: 10.0 points). The DASH-Score revealed better results for PDS group (3.4 points, HP: 8.0 points). Signs of acromial osteolysis appeared in five cases (18.5%) in HP group. There was no case of implant failure. The X-rays of six patients (HP: 4, PDS: 2) showed AC-joint-osteoarthritis.

CONCLUSION: Hook plate fixation employing a polyaxial angular stable plate finally restores the coracoclavicular distance more accurately than augmentation with a PDS sling. Although in HP group no implant failure occurred, major disadvantages are initial overcorrection and acromial osteolysis. Both have no influence on final functional results.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app