We have located links that may give you full text access.
Comparative Study
Evaluation Studies
Journal Article
Meta-Analysis
Diagnostic accuracy of real-time polymerase chain reaction in detection of Clostridium difficile in the stool samples of patients with suspected Clostridium difficile Infection: a meta-analysis.
Clinical Infectious Diseases 2011 October
BACKGROUND: Current detection methods for Clostridium difficile infection (CDI) can be time-consuming and have variable sensitivities. Real-time polymerase chain reaction (PCR) may allow earlier and more accurate diagnosis of CDI than other currently available diagnostic tests. A meta-analysis was performed to determine the diagnostic accuracy of real-time PCR.
METHODS: We searched MEDLINE (Pubmed/Ovid) and 4 other online electronic databases (1995-2010) to identify diagnostic accuracy studies that compared PCR with cell culture cytotoxicity neutralization assay (CCCNA) or anaerobic toxigenic culture (TC) of C. difficile. Screening for inclusion, data extraction, and quality assessment were carried out independently by 2 investigators and disagreements resolved. Data were combined by means of a random-effects model, and summary receiver operating characteristic curves and diagnostic odds ratios were calculated.
RESULTS: Nineteen studies (7392 samples) met our inclusion criteria. The overall mean sensitivity of PCR was 90% (95% confidence interval [CI]: 88%-91%), specificity 96% (CI: 96%-97%), positive likelihood ratio 26.89 (CI: 20.81-34.74), negative likelihood ratio 0.11 (CI: .08-.15), diagnostic odds ratio 278.23 (CI: 213.56-362.50), and area under the curve 0.98 (CI: .98-.99). Test accuracy depended on the prevalence of C. difficile but not on the reference test used. At C. difficile prevalence of <10%, 10%-20% and >20% the positive predictive value and the negative predictive value were 71%, 79%, 93% and 99%, 98% and 96%, respectively.
CONCLUSIONS: Real-time PCR has a high sensitivity and specificity to confirm CDI. Overall diagnostic accuracy is variable and depends on CDI prevalence.
METHODS: We searched MEDLINE (Pubmed/Ovid) and 4 other online electronic databases (1995-2010) to identify diagnostic accuracy studies that compared PCR with cell culture cytotoxicity neutralization assay (CCCNA) or anaerobic toxigenic culture (TC) of C. difficile. Screening for inclusion, data extraction, and quality assessment were carried out independently by 2 investigators and disagreements resolved. Data were combined by means of a random-effects model, and summary receiver operating characteristic curves and diagnostic odds ratios were calculated.
RESULTS: Nineteen studies (7392 samples) met our inclusion criteria. The overall mean sensitivity of PCR was 90% (95% confidence interval [CI]: 88%-91%), specificity 96% (CI: 96%-97%), positive likelihood ratio 26.89 (CI: 20.81-34.74), negative likelihood ratio 0.11 (CI: .08-.15), diagnostic odds ratio 278.23 (CI: 213.56-362.50), and area under the curve 0.98 (CI: .98-.99). Test accuracy depended on the prevalence of C. difficile but not on the reference test used. At C. difficile prevalence of <10%, 10%-20% and >20% the positive predictive value and the negative predictive value were 71%, 79%, 93% and 99%, 98% and 96%, respectively.
CONCLUSIONS: Real-time PCR has a high sensitivity and specificity to confirm CDI. Overall diagnostic accuracy is variable and depends on CDI prevalence.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app