Assessment of the American Society of Echocardiography-European Association of Echocardiography guidelines for diastolic function in patients with depressed ejection fraction: an echocardiographic and invasive haemodynamic study.

AIMS: There is controversy surrounding the accuracy of echo-Doppler variables, including early mitral inflow/mitral annular velocity (E/e'), for estimating left ventricular filling pressure (LVFP) in patients with depressed ejection fraction (EF < 50%).

METHODS AND RESULTS: The American Society of Echocardiography-European Association of Echocardiography (ASE-EAE) algorithm for diastolic function in depressed LVEF was retrospectively applied to a database of patients who underwent echocardiography ≤20 min of cardiac catheterization. LV pre-atrial contraction pressure (pre-A) ≥15 mmHg was elevated. Of 62 patients studied, the mean age was 53.6 ± 10.6 years and the mean LVEF was 27.2 ± 11.8%. The correlations of E/e' (R = 0.43, P = 0.0005) and E (R = 0.39, P = 0.002) with LV pre-A were modest, compared with pulmonary artery pressure (PAP, R = 0.69, P = 0.0006), E/late mitral (A) velocity (R = 0.52, P < 0.0001), and mitral deceleration time (DT, R = -0.51, P < 0.0001). Using the ASE-ESE algorithm starting with E/A, E, and DT, 54 of 62 patients were accurately classified to predict LV pre-A >15 or <15 mmHg (sensitivity = 84%, specificity = 80%, area under the curve = 0.86, P < 0.001). The 6 of 6 patients with E/A < 1 and E < 50 and the 14 of 15 (93%) patients with E/A> 2 and DT < 150 were correctly classified as having normal and elevated LVFP, respectively, while 34 of 41 (83%) patients with E/A = 1-2 or E/A<1 and E>50 cm/s were correctly classified using the addition of E/e' and PAP.

CONCLUSION: This retrospective study shows that in this population with depressed LVEF, no single echo-Doppler variable had high accuracy for predicting LV pre-A ≥15 mmHg. However, the ASE-EAE algorithm using multiple variables predicted LVFP with good accuracy, superior to any single echo-Doppler variable alone.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app