Residual setup errors and dose variations with less-than-daily image guided patient setup in external beam radiotherapy for esophageal cancer.
Radiotherapy and Oncology 2012 Februrary
BACKGROUND AND PURPOSE: To evaluate residual patient setup errors and daily dose variations of different less-than-daily image guidance (IG) strategies in the delivery of external beam radiotherapy for esophageal cancer.
MATERIAL AND METHODS: Daily image-guided setup data for 25 consecutive esophageal cancer patients treated with helical tomotherapy were evaluated. Seven less-than-daily IG strategies with different imaging frequencies were simulated. For each IG strategy, the daily residual setup errors were calculated. Using TomoTherapy Planned Adaptive software, daily dose variations to the clinical target volume, heart, and lungs were evaluated in five representative patients.
RESULTS: With 0% (60%) IG frequency, the margins required for adequate coverage of the clinical target volume were 13 mm (10 mm), 14 mm (11 mm), and 5 mm (5 mm) in the left-right, superior-inferior, and anterior-posterior directions, respectively. Even with 60% IG frequency, 10% of the fractions had more than 10% decrease in the dose level covering 95% of the target, and 14% and 13% of the fractions had more than 10% increase in total lung volume receiving at least 0.8 Gy per fraction, and heart volume receiving at least 1.2 Gy per fraction, respectively.
CONCLUSION: Substantial residual setup errors would occur for treatment fractions without IG even if the most frequent less-than-daily IG strategy was to be used, which could lead to significant daily dose variations for the target volume and adjacent normal tissues. Daily image guidance is recommended throughout the course of treatment in conformal radiotherapy for esophageal cancer.
MATERIAL AND METHODS: Daily image-guided setup data for 25 consecutive esophageal cancer patients treated with helical tomotherapy were evaluated. Seven less-than-daily IG strategies with different imaging frequencies were simulated. For each IG strategy, the daily residual setup errors were calculated. Using TomoTherapy Planned Adaptive software, daily dose variations to the clinical target volume, heart, and lungs were evaluated in five representative patients.
RESULTS: With 0% (60%) IG frequency, the margins required for adequate coverage of the clinical target volume were 13 mm (10 mm), 14 mm (11 mm), and 5 mm (5 mm) in the left-right, superior-inferior, and anterior-posterior directions, respectively. Even with 60% IG frequency, 10% of the fractions had more than 10% decrease in the dose level covering 95% of the target, and 14% and 13% of the fractions had more than 10% increase in total lung volume receiving at least 0.8 Gy per fraction, and heart volume receiving at least 1.2 Gy per fraction, respectively.
CONCLUSION: Substantial residual setup errors would occur for treatment fractions without IG even if the most frequent less-than-daily IG strategy was to be used, which could lead to significant daily dose variations for the target volume and adjacent normal tissues. Daily image guidance is recommended throughout the course of treatment in conformal radiotherapy for esophageal cancer.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app