Add like
Add dislike
Add to saved papers

Results of 131 consecutive operated patients with a displaced proximal humerus fracture: an analysis with more than two years follow-up.

OBJECTIVE: The purpose of this study is to determine the efficacy of the open reduction and fixation of a dislocated proximal humerus fracture with a locking plate, also evaluating the incidence of complications and functional recovery of the shoulder. A retrospective study focusing on patients who had suffered a fracture of the proximal humerus and were treated by means of an open reduction and internal fixation with a locking plate, using either the Philos or the LPHP plate. We have also included a comparison of these two plates. METHOD: Ninety-two patients were found to be eligible and were included in our study. These patients had all been treated for a proximal humerus fracture between 2002 and 2008. We included those patients who could be classified as a class 2, 3, or 4 according to the Neer classification. Demographic data, surgical technique, and peri/post-operative complications were collected from medical records. Patients were followed-up and the Oxford Shoulder Score (OSS) was filled in by phone. The mean age of our patient population was 66.2 (15-97), with a male: female ratio of 1:5 (15:77). (The median follow-up was 2.4 years (0.2-5.8). Fourteen of our patients died during follow-up, while 25 patients were otherwise lost to follow-up. For this study, out of the original 131 patients, this finally resulted in 92 patients whom we followed-up post-operatively. RESULTS: Ninety-two patients (70%, 92/131) were interviewed. The mean Oxford Shoulder Score (OSS) was 19.76 (11-54). The overall complication rate was 39.1% (36/92). The most frequently occurring complications in our patient population were hemorrhage 3.3%; dislocation of the caput humeri and/or tuberculum majus 2.2%; persistent pain 3.3%; Avascular necrosis (AVN) of the humeral head 0%; Loss of reduction and screw cutout 6.5%; Plate breakout 6.5%; Subacromial Impingement 11.9%; Frozen shoulder 3.3%; rotator cuff rupture 1.1%, and infection 1.1%. Of the entire group of patients originally included in this study, 29% was re-operated due to one of the above-mentioned complications. CONCLUSION: In conclusion, the locking plate provides satisfactory functional outcomes after a mid-term follow-up in patients with displaced proximal humerus fractures. The incidence of complications and subsequent re-operation is relatively high, however, comparable to or slightly better when compared to data found in literature. Subacromial Impingement seems to occur more frequently when a Philos plate is implemented. We therefore suggest that randomized clinical trials determining the possible superiority of one specific type of plate in patients with a displaced proximal humerus fracture are to be performed in future.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app