Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction.

PURPOSE: To assess the impact of body mass index (BMI)-adapted protocols and iterative reconstruction algorithms (iDose) on patient radiation exposure and image quality in patients undergoing prospective ECG-triggered 256-slice coronary computed tomography angiography (CCTA).

METHODS: Image quality and radiation exposure were systematically analyzed in 100 patients. 60 Patients underwent prospective ECG-triggered CCTA using a non-tailored protocol and served as a 'control' group (Group 1: 120 kV, 200 mAs). 40 Consecutive patients with suspected coronary artery disease (CAD) underwent prospective CCTA, using BMI-adapted tube voltage and standard (Group 2: 100/120 kV, 100-200 mAs) versus reduced tube current (Group 3: 100/120 kV, 75-150 mAs). Iterative reconstructions were provided with different iDose levels and were compared to filtered back projection (FBP) reconstructions. Image quality was assessed in consensus of 2 experienced observers and using a 5-grade scale (1=best to 5=worse), and signal- and contrast-to-noise ratios (SNR and CNR) were quantified.

RESULTS: CCTA was performed without adverse events in all patients (n=100, heart rate of 47-87 bpm and BMI of 19-38 kg/m2). Patients examined using the non-tailored protocol in Group 1 had the highest radiation exposure (3.2±0.4 mSv), followed by Group 2 (1.7±0.7 mSv) and Group 3 (1.2±0.6 mSv) (radiation savings of 47% and 63%, respectively, p<0.001). Iterative reconstructions provided increased SNR and CNR, particularly when higher iDose level 5 was applied with Multi-Frequency reconstruction (iDose5 MFR) (14.1±4.6 versus 21.2±7.3 for SNR and 12.0±4.2 versus 18.1±6.6 for CNR, for FBP versus iDose5 MFR, respectively, p<0.001). The combination of BMI adaptation with iterative reconstruction reduced radiation exposure and simultaneously improved image quality (subjective image quality of 1.4±0.4 versus 1.9±0.5 for Group 2 reconstructed using iDose5 MFR versus Group 1 reconstructed using FBP, p<0.05).

CONCLUSIONS: Prospective ECG-triggered 256-slice CCTA allows for visualization of the coronary artery tree with high image quality within a wide range of heart rates and BMIs. The combination of BMI-adapted protocols with iterative reconstruction algorithms can reduce radiation exposure for the patients and simultaneously improve image quality.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app