Evaluation Studies
Journal Article
Add like
Add dislike
Add to saved papers

Therapeutic application of ultrasound-guided 8-gauge Mammotome system in presumed benign breast lesions.

Breast Journal 2011 September
The stereotactic or ultrasound-guided vacuum-assisted breast biopsy (Mammotome, MMT) system is a minimally invasive surgical technique. Increasingly, it is used to remove benign breast lesions as management. To evaluate the therapeutic value of 8-gauge ultrasound-guided MMT system (UMS) in presumed benign breast lesions, a retrospective analysis was performed on a series of 2,167 consecutive 8-gauge UMS procedures. The parameters used in this analysis included lesion size, location, breast imaging reporting and data system for ultrasound category, histopathologic diagnosis, and others. A total of 1,119 women whose mean ages were 36.6 years (range: 12-71, SD: 9.6) underwent 2,167 consecutive 8-gauge UMS procedures. Among the patients, 298 cases (26.63%) did not have palpable mass, 430 (38.43%) had multiple lesions, and 237 (21.18%) had bilateral ones. The average size of excised lesions was 15.8 mm (range: 5-55, SD: 6.7) in the largest dimension, including 294 lesions < 10 mm (13.57%); 1,359 lesions, 10-19 mm (62.71%); 420 lesions, 20-29 mm (19.38%), and 94 lesions ≥ 30 mm (4.34%). Predominant lesions (81.59%) were solid on ultrasound image and nearly half (48.59%) of them were localized in the upper outer quadrant. Histopathologic diagnosis revealed that the overwhelming majority of specimens (96.61%) were benign, most of which manifested as fibroadenoma and fibrocystic changes, while high-risk lesions were revealed in 31 (2.29%) cases and malignancies in 15 (1.11%). Average time for procedure was 8.6 minutes (range: 3.5-38, SD: 5.4) and mean number of cores removed in the procedure was 9.3 (range: 2-42, SD: 3.7). Complete excision was achieved predominantly (99.82%). Complications (59, 5.27%) in which hematoma (41, 3.66%) was the majority were acceptable. In conclusion, the 8-gauge UMS procedure is a safe and potent therapeutic management with satisfactory cosmetic outcome for benign and high-risk breast lesions, especially for bilateral, multiple, and nonpalpable ones. It is a reliable biopsy tool for suspected lesions as well. Eradication and maximal cosmesis can be achieved with few complications if the targeted lesion is limited to 30 mm.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app