JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

The long-term survival and the risks and benefits of implantable cardioverter defibrillators in patients with hypertrophic cardiomyopathy.

Heart 2012 January
OBJECTIVE: Implantable cardioverter defibrillators (ICDs) are routinely used to prevent sudden cardiac death (SCD) in selected hypertrophic cardiomyopathy (HCM) patients, but the determinants of device-related complications, therapies and long-term cardiovascular mortality in ICD recipients are not known.

DESIGN: Retrospective observational cohort study.

SETTING: Single-centre tertiary referral cardiomyopathy clinic. Patients 334 consecutively evaluated HCM patients (median age 40 years, 62% male, 92% primary prevention) at risk of SCD treated with ICD. Thirty-six patients (11%) received concurrent cardiac resynchronisation therapy for heart failure symptoms.

RESULTS: During the 1286 patient-years of follow-up, cardiovascular mortality (including transplantation) occurred in 22 (7%) patients (1.7%/year) and was associated with New York Heart Association (NYHA) class III/IV (adjusted HR=9.38, 95% CI 3.31 to 26.55, p≤0.001), percentage fractional shortening (HR=0.92, 95% CI 0.87 to 0.96, p=0.001) and implantation for secondary prevention (HR=0.07, 95% CI 0.01 to 0.86, p=0.04). There were no SCD. Twenty-eight (8%) patients received appropriate shocks (2.3%/year), which were predicted by baseline fractional shortening (HR=0.96, 95% CI 0.92 to 0.99, p=0.04). Fifty-five (16%) patients received inappropriate shocks (4.6%/year). Sixty (18%) patients experienced implant-related complications (5.1%/year), including two deaths. Adverse ICD-related events (inappropriate shocks and/or implant complications) were seen in 101 (30%) patients (8.6%/year). Patients with cardiac resynchronisation therapy were more likely to develop implant complications than those with single-chamber ICDs (HR=4.39, 95% CI 1.44 to 13.35, p=0.009) and had a higher 5-year cardiovascular mortality than did the rest of the cohort (21% vs 6%, p<0.001).

CONCLUSIONS: HCM patients with an ICD have a significant cardiovascular mortality and are exposed to frequent inappropriate shocks and implant complications. These data suggest that new strategies are required to improve patient selection for ICDs and to prevent disease progression in those that receive a device.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app