JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Automated measurement of the arteriolar-to-venular width ratio in digital color fundus photographs.

A decreased ratio of the width of retinal arteries to veins [arteriolar-to-venular diameter ratio (AVR)], is well established as predictive of cerebral atrophy, stroke and other cardiovascular events in adults. Tortuous and dilated arteries and veins, as well as decreased AVR are also markers for plus disease in retinopathy of prematurity. This work presents an automated method to estimate the AVR in retinal color images by detecting the location of the optic disc, determining an appropriate region of interest (ROI), classifying vessels as arteries or veins, estimating vessel widths, and calculating the AVR. After vessel segmentation and vessel width determination, the optic disc is located and the system eliminates all vessels outside the AVR measurement ROI. A skeletonization operation is applied to the remaining vessels after which vessel crossings and bifurcation points are removed, leaving a set of vessel segments consisting of only vessel centerline pixels. Features are extracted from each centerline pixel in order to assign these a soft label indicating the likelihood that the pixel is part of a vein. As all centerline pixels in a connected vessel segment should be the same type, the median soft label is assigned to each centerline pixel in the segment. Next, artery vein pairs are matched using an iterative algorithm, and the widths of the vessels are used to calculate the AVR. We trained and tested the algorithm on a set of 65 high resolution digital color fundus photographs using a reference standard that indicates for each major vessel in the image whether it is an artery or vein. We compared the AVR values produced by our system with those determined by a semi-automated reference system. We obtained a mean unsigned error of 0.06 (SD 0.04) in 40 images with a mean AVR of 0.67. A second observer using the semi-automated system obtained the same mean unsigned error of 0.06 (SD 0.05) on the set of images with a mean AVR of 0.66. The testing data and reference standard used in this study has been made publicly available.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app