CONTROLLED CLINICAL TRIAL
JOURNAL ARTICLE
MULTICENTER STUDY
Add like
Add dislike
Add to saved papers

A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results.

BACKGROUND: Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently, investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease.

METHODS: A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group: 168 patients; ENDEAVOR group: 156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length ≤ 40 mm, reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years, including major adverse cardiac events (cardiac death, myocardial infarction, or target-lesion revascularization) and stent thrombosis.

RESULTS: Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25 ± 0.33) mm vs. (0.57 ± 0.55) mm, diff (95%CI) -0.23 (-0.32, -0.14), P < 0.0001; in-segment (0.25 ± 0.33) mm vs. (0.42 ± 0.55) mm, diff (95%CI) -0.13 (-0.23, -0.02), P = 0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P = 0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P = 0.0495) at 2 years. The two-year major adverse cardiac events (MACE) rate was lower for the TIVOLI group, but not significantly different (6.6% vs. 10.9%, P = 0.1630).

CONCLUSIONS: TIVOLI was superior to ENDEAVOR stent with respect to late lumen loss at 8 months, and it yielded both lower rates of angiographic binary restenosis at 8 months and target lesion revascularization (TLR) at 2 years. The MACE rate at 2 years was comparable in both groups.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app