COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Responses to dural puncture during institution of combined spinal-epidural analgesia: a comparison of 27 gauge pencil-point and 27 gauge cutting-edge needles.

Pencil-point spinal needles are popular for combined spinal-epidural analgesia because they cause less dural puncture headache than cutting-edge spinal needles. However many parturients move, grimace, vocalise or experience paraesthesia or dysaesthesia during dural puncture when performing 'needle through needle' combined spinal-epidural analgesia. We compared dural puncture responses induced by pencil-point and cutting-edge needles (both 27 gauge). With institutional approval, 115 parturients presenting for elective caesarean section or labour analgesia were audited. After lignocaine infiltration, a Tuohy-type needle was inserted to loss of resistance to saline at a mid-lumbar interspace, and either a 27 gauge cutting-edge or 27 gauge pencil-point needle was inserted 'needle through needle' through the dura. During dural penetration, the occurrence of patient movement, grimacing or vocalisation was noted by a blinded observer, as was the patient's response to the question "Did you feel that?" asked by the anaesthetist. The audit comprised two similar groups of patients (caesarean section, n=30; labour analgesia, n=85). In both groups, grimacing and movement during thecal penetration occurred more frequently with pencil-point needles (P < 0.05 and P < 0.025, respectively). Pooled data analysis revealed that pencil-point and cutting-edge needles induced grimacing and movement in 17 (22%) and 2 (5%), spontaneous vocalisation in 4 (5%) and 1 (3%) and was perceived by 13 (17%) and 3 (8%) parturients (P < 0.025, P=NS, P=NS), respectively. Overall, 34 and 6 objective and subjective patient responses (P < 0.005) occurred when inserting these needles, respectively. Dural puncture by a 27 gauge pencil-point needle inserted 'needle through needle' when instituting combined spinal-epidural analgesia induces more iatrogenic responses than a 27 gauge cutting-edge needle.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app