Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Effects of cartilage remnants of the posterior femoral condyles on femoral component rotation in varus knee osteoarthritis.

Knee 2012 June
Preoperative planning of total knee arthroplasty (TKA) based on computerized tomography (CT) data can produce a femoral rotational error due to lack of information on the femoral cartilage thickness. The research question of this study is how much femoral rotational error is expected due to the cartilage remnants when using the posterior condylar angles (PCA, angle between the posterior condylar line and the surgical epicondylar axis (SEA)) on CT data. CT arthrography was performed for 35 consecutive varus osteoarthritic knees in 31 patients who underwent TKA, on which the cartilage thicknesses of the posterior femoral condyles were measured. The PCAs when including or excluding the cartilage remnants were also measured. The cartilage thicknesses of the medial and lateral posterior condyles averaged 0.39mm (SD=0.53) and 1.55mm (SD=0.26), respectively (p<0.0001). When the cartilage was included or excluded, the PCA averaged 2.2° (SD=1.5) and 3.3° (SD=1.5), respectively (p=0.002). The cartilage remnants in the posterior femoral condyles produced an average of 1.1° and a maximum of 2.1° of additional femoral external rotation when using CT data for the preoperative planning. CT scan measurements of femoral rotation are subject to error. Although this is said to be small and within the safety margin for setting the femoral component parallel to the trans-epicondylar axis, this difference should be considered by surgeons who use the posterior condylar axis, in order to avoid excessive external rotation of the femoral component.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app