Magnetic resonance VIBE venography using the blood pool contrast agent gadofosveset trisodium--an interrater reliability study.
European Journal of Radiology 2012 March
PURPOSE: In this study, image quality of leg veins and vena cava inferior was scored by independent raters using the new intravascular magnetic resonance imaging (MRI) contrast agent gadofosveset trisodium using fat-suppressed 3D gradient echo Volume Interpolated Breath-hold Examination.
MATERIAL AND METHODS: The leg venous system without clinical signs of deep venous thrombosis (DVT) and sonography-ruled out DVT were imaged using a fat-suppressed 3D gradient echo Volume Interpolated Breath-hold Examination (VIBE FS). Image interpretation was done independently by two experienced radiologists (raters) using a 5-point scoring system.
RESULTS: High diagnostic image quality with an overall mean visibility score of 4.8±0.1 was acquired in patients enrolled in the study using gadofosveset trisodium-enhanced MRI for the venous system of the leg. There were no cases with moderate, poor or nondiagnostic image quality. Additionally, an excellent interrater reliability was observed.
CONCLUSIONS: This study shows the feasibility of acquiring high resolution images with excellent image quality of the venous system of the leg using gadofosveset trisodium.
MATERIAL AND METHODS: The leg venous system without clinical signs of deep venous thrombosis (DVT) and sonography-ruled out DVT were imaged using a fat-suppressed 3D gradient echo Volume Interpolated Breath-hold Examination (VIBE FS). Image interpretation was done independently by two experienced radiologists (raters) using a 5-point scoring system.
RESULTS: High diagnostic image quality with an overall mean visibility score of 4.8±0.1 was acquired in patients enrolled in the study using gadofosveset trisodium-enhanced MRI for the venous system of the leg. There were no cases with moderate, poor or nondiagnostic image quality. Additionally, an excellent interrater reliability was observed.
CONCLUSIONS: This study shows the feasibility of acquiring high resolution images with excellent image quality of the venous system of the leg using gadofosveset trisodium.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app