Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Relation of brachial and digital measures of vascular function in the community: the Framingham heart study.

Hypertension 2011 March
Impaired vascular function contributes to the development of clinical cardiovascular disease. The relation between vasodilator function assessed noninvasively in the brachial and digital arteries remains incompletely defined. In the Framingham Offspring, Third Generation and Omni Cohorts, we measured flow-mediated dilation (FMD; n = 7031; age 48 ± 13 years; age range, 19 to 88 years; 54% women) and peripheral arterial tonometry (PAT) ratio (n = 4352; 55 ± 16 years; age range, 19 to 90 years; 51% women). Abnormal vascular function for each measure was defined by the sex-specific fifth percentile in a reference group free of conventional cardiovascular risk factors. The prevalence of abnormal FMD but not abnormal PAT ratio was higher with advancing age. In multivariable models, higher body mass index was associated with a higher prevalence of both abnormal FMD and PAT ratio. Additional correlates of abnormal FMD included increasing age and higher systolic blood pressure. In contrast, correlates of abnormal PAT ratio included lower systolic blood pressure, increasing total/high-density lipoprotein cholesterol ratio, diabetes, smoking, and lipid-lowering medication. Whereas women had higher FMD and PAT ratios compared with men, using sex-specific reference values, women had a higher prevalence of abnormal brachial and digital vascular function. In participants who had concurrent testing (n = 1843), PAT ratio was not significantly associated with FMD in multivariable models. In this large, community-based cohort, brachial and digital measures of vascular function had differing relations with cardiovascular risk factors and were nearly uncorrelated with each other. These results suggest that FMD and PAT provide distinct information regarding vascular function in conduit versus smaller digital vessels.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app