We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Hemostatic effects of fresh frozen plasma may be maximal at red cell ratios of 1:2.
Journal of Trauma 2011 January
BACKGROUND: Damage control resuscitation targets acute traumatic coagulopathy with the early administration of high-dose fresh frozen plasma (FFP). FFP is administered empirically and as a ratio with the number of packed red blood cells (PRBC). There is controversy over the optimal FFP:PRBC ratio with respect to outcomes, and their hemostatic effects have not been studied. We report preliminary findings on the effects of different FFP:PRBC ratios on coagulation.
METHODS: This is a prospective observational cohort study of trauma patients requiring >4 U of PRBCs. Blood was drawn before and after each 4-U PRBC interval for prothrombin time and analysis by rotational thromboelastometry. Interval change in coagulation parameters were compared with the FFP:PRBC ratio received during each interval.
RESULTS: Sixty 4-U PRBC intervals from 50 patients were available for analysis. All measures of coagulation deteriorated with low FFP:PRBC ratios (<1:2). Maximal hemostatic effect was observed in the 1:2 to 3:4 group: 12% decrease in prothrombin time (p=0.006), 56% decrease in clotting time (p=0.047), and 38% increase in maximum clot firmness (p=0.024). Transfusion with ≥1:1 ratio did not confer any additional improvement. There was a marked variability in response to FFP, and hemostatic function deteriorated in some patients exposed to 1:1 ratios. The beneficial effects of plasma were confined to patients with coagulopathy.
CONCLUSIONS: Interim results from this prospective study suggest that FFP:PRBC ratios of ≥1:1 do not confer any additional advantage over ratios of 1:2 to 3:4. Hemostatic benefits of plasma therapy are limited to patients with coagulopathy.
METHODS: This is a prospective observational cohort study of trauma patients requiring >4 U of PRBCs. Blood was drawn before and after each 4-U PRBC interval for prothrombin time and analysis by rotational thromboelastometry. Interval change in coagulation parameters were compared with the FFP:PRBC ratio received during each interval.
RESULTS: Sixty 4-U PRBC intervals from 50 patients were available for analysis. All measures of coagulation deteriorated with low FFP:PRBC ratios (<1:2). Maximal hemostatic effect was observed in the 1:2 to 3:4 group: 12% decrease in prothrombin time (p=0.006), 56% decrease in clotting time (p=0.047), and 38% increase in maximum clot firmness (p=0.024). Transfusion with ≥1:1 ratio did not confer any additional improvement. There was a marked variability in response to FFP, and hemostatic function deteriorated in some patients exposed to 1:1 ratios. The beneficial effects of plasma were confined to patients with coagulopathy.
CONCLUSIONS: Interim results from this prospective study suggest that FFP:PRBC ratios of ≥1:1 do not confer any additional advantage over ratios of 1:2 to 3:4. Hemostatic benefits of plasma therapy are limited to patients with coagulopathy.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app