Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation.

BACKGROUND: The complicated anatomy of the cervical spine and the variation among pedicles reduces the accuracy and increases the risk of neurovascular complications associated with screw implantation in this region. In this study, we compared the accuracy of cervical (C2-C7) pedicle screw fixation assisted by X-ray fluoroscopy, computed tomography (CT)-based navigation, or intraoperative three-dimensional (3D) C-arm navigation.

METHODS: This prospective cohort study was performed in 82 consecutive patients who underwent cervical pedicle screw fixation. The accuracy of screw insertion was assessed by postoperative CT scan with 3D reconstruction. The accuracy of screw insertion was assessed as: excellent (screw completely within pedicle); acceptable (≤ 1 mm screw outside pedicle cortex); poor (> 1 mm screw outside pedicle cortex).

RESULTS: A total of 145 screws were inserted in 24 patients who underwent C-arm fluoroscopy. Of these, 96 screws (66.2%) were excellent, 37 (25.5%) were acceptable, and 12 (8.3%) were poor. One hundred and fifty-nine screws were inserted in 29 patients in the CT-based navigation group. Among these, 141 (88.7%) were excellent, 14 (8.8%) were acceptable, and 4 (2.5%) were poor. A total of 140 screws were inserted in 29 patients in the intraoperative 3D C-arm navigation group, of which 127 (90.7%) were excellent, and 13 (9.3%) were acceptable. No severe or permanent neurovascular complications associated with screw insertion were observed in any patient.

CONCLUSIONS: CT-based and intraoperative 3D C-arm navigation were similarly accurate, and were both significantly more accurate than C-arm fluoroscopy for guiding cervical pedicle screw fixation. They were able to accurately guide the angle and depth of screw placement using visual 3D images. These two techniques are therefore preferable for high-risk cervical pedicle screw fixation. The ease and convenience of intraoperative 3D C-arm navigation suggests that it may replace virtual-fluoroscopy and CT-based navigation systems in future clinical applications.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app